300-540 practice questions
Cisco · 300-540 · 300 questions
Original practice questions for the Designing and Implementing Cisco Service Provider Cloud Network Infrastructure v1.0 (300-540 SPCNI) exam, covering every domain of the official exam objectives.
This course contains the use of artificial intelligence.
About the 300-540 exam
- Questions
- not published
- Passing score
- not published
- Format
- 90-minute exam associated with the CCNP Service Provider certification
Schedule this exam The certification this earns
Exam details published by the vendor, checked 9 November 2026. Vendors change fees and formats without notice — confirm on the vendor's own page before you book.
Practice Quizzes
Test your knowledge with standard 20-question practice sets.
Quiz 1
Quiz 2
Quiz 3
Quiz 4
Quiz 5
Quiz 6
Quiz 7
Quiz 8
Quiz 9
Quiz 10
Quiz 11
Quiz 12
Quiz 13
Quiz 14
Quiz 15
Browse by Domain
Study specific topics at your own pace.
Virtualized Architecture (25%) · 75 questions
- A metro utility has a YANG module that describes a VPN on its virtual router, and it has not opened a management session to that router. An engineer expects the VPN to appear because the module exists. What is missing?
- A hospital tenant on infrastructure as a service asks the cloud operator to reset the administrator password inside the imaging guest. The hypervisor is healthy. Who owns that password change?
- A provider runs a virtual firewall as a workload on its cloud and uses a separate system to push service intent. What is that virtual firewall in the design?
- A tenant must patch its own guest operating system while the provider operates the compute pool under that guest. Which cloud service model fits?
- Bridged tenant isolation has consumed every usable 802.1Q VLAN identifier, the 4094 values from 1 through 4094. New tenants still need isolation. Which design removes that limit?
- A university team on platform as a service wants to load a kernel module on the host that runs their enrollment application. The team can already deploy new application builds. Who owns that host change?
- A mobile carrier already accepted the NFV approach and already runs an orchestrator for service intent. Subscriber flows still need a guest that inspects and filters packets. What should be placed on the compute hosts?
- A usage-rating hook must run only when a billing event arrives. The tenant must not patch a guest operating system or keep a long-lived runtime for that hook. Which service model matches the hook?
- A virtual router is already onboarded with an image, a flavor, and day-0 reachability. One VPN description must now be applied the same way on several provider routers. Which system does that job?
- A regional healthcare group is standardizing automation for its clinic edge routers and needs validated, model-driven configuration that checks against device data models. Which automation approach meets that requirement?
- A weather bureau wants forecast code to run when a new file arrives and does not want a guest operating system left behind to patch. Which cloud service model matches that split of responsibility?
- An infrastructure cloud bridges every tenant network on one Layer 2 domain and has used all 4094 usable 802.1Q identifiers. New tenants still need isolation from one another. Which design removes that constraint?
- A hosting provider has already assigned every usable bridged identifier from 1 through 4094 on one domain and still needs more isolated tenants. How should new tenant segmentation be built?
- A rail laboratory must run a vendor track probe that ships with its own kernel and must keep its own guest kernel separate from other workloads under a trusted hypervisor. Which placement meets that requirement?
- A virtual firewall is already running on the cloud. The provider wants one system to push the same service intent to that firewall and to the physical edges. Which system has that role?
- A ferry operator still has unused 802.1Q identifiers inside 1 through 4094. The next tenant needs one isolated bridged segment and no other networks. Use the existing bridged fabric and minimize new infrastructure or encapsulation. What should be allocated?
- A carrier needs the firewall function that inspects tenant packets on the cloud, not the method name and not the system that pushes service intent. What should the carrier select?
- For this OpenStack deployment, a harbor has a virtual firewall image registered in the catalog, but no flavor is chosen for launch and the instance has never booted. What missing piece belongs to onboarding?
- A catalog team ships a stateless web front end built to run as a process on the host kernel and to be scheduled in many copies. Which placement matches that workload?
- A dental group will use a scheduling application whose vendor runs the application and the guest. The group does not receive a guest or a runtime. Which service model is this?
- A mobile-core team must create a virtual router instance, choose its flavor, and attach day-0 networks before any wide-area service intent exists. Which system performs that instantiation?
- A research campus has assigned every usable 802.1Q identifier from 1 through 4094. A new lab still needs one isolated Layer 2 segment so two appliances can exchange broadcasts. What should carry it?
- A museum operates the compute pool in its own building, patches every guest itself, and does not burst onto a provider-operated pool. Which cloud model is this?
- A port authority already has the image and the flavor for a virtual firewall in its VIM, yet nothing can reach the instance for first-time configuration. What gives the instantiated firewall its first management reachability?
- A parks department runs a map-tile renderer built to share the host kernel and scheduled as a process. It does not boot its own kernel and does not need a separate guest boundary. What should host it?
- A power utility already runs many virtual CGNAT guests that operators edit by hand. Leadership wants one policy applied the same way on every guest. What role is missing?
- In a design review a metro operator must name the virtual router image that forwards tenant packets, as distinct from the system that pushes intent and from the general virtualization approach. What is that router image?
- A studio automation host has a working NETCONF session to a virtual router, and gNMI subscriptions to that same router still fail. The router supports gNMI. The client opens only the NETCONF connection and never establishes a gRPC connection to the gNMI service. What explains the failed subscriptions?
- A municipal transit operator is placing a virtual firewall on shared cloud compute and must name that firewall function itself, separate from the virtualization approach and from the system that pushes service intent. What should the firewall function be called?
- A research bureau must run a climate model on a kernel the host does not use, with a strong boundary around that guest. What should host the model?
- A mobile-core team must create a tenant network and boot a virtual gateway on the hosted OpenStack cloud. The provider-edge routers are already configured. Which interface performs that create-and-boot action?
- Several virtual routers are already onboarded. A transit provider now needs one L3VPN intent pushed consistently to all of them. What performs that job?
- A shipyard needs a virtual router that speaks BGP and forwards tenant packets in the hosted cloud. The orchestration system that pushes service intent is already running and healthy. What still has to be placed?
- A transit agency keeps its guest images, operates the steady pool itself, and bursts those same guests onto a provider-operated pool. Which arrangement is that?
- A cable operator wants one system to push service intent for a virtual router service across the devices that implement it. Which component does that orchestration?
- An insurer’s OpenStack claims VM boots from a Nova-provisioned ephemeral root disk, not a Cinder volume. The guest writes claim files only to that disk. The instance is deleted and a new one is booted from the same image. The files are gone. Which constraint explains that loss?
- A retail chain uses a vendor scheduling application delivered as software as a service. The chain wants to replace that application's binary with its own build. The chain can already edit its store data and its tenant settings. Who owns the binary change?
- A port authority's virtual firewall is dropping subscriber packets. The orchestration system that pushes service intent is idle, and its order rate is normal. Firewall resource counters confirm forwarding-capacity exhaustion, with no policy-deny, storage or link fault. A ticket says to scale the NFV by adding orchestrator capacity. What should be scaled?
- An insurer wants its own short rating function to run only when a claim event arrives, with no guest and no standing runtime left to patch. Which service model fits that function?
- During a data-hall renovation a regional bank must run guest images it still patches on a pool a public provider operates. Which arrangement matches that split of duties?
- One bridged fabric already uses every 802.1Q identifier from 1 through 4094, and a new tenant still needs isolation. Which design adds that tenant?
- A virtual firewall image and its flavor are already registered on the VIM, but the instance boots with no management reachability. What gives the instantiated firewall its first management reachability?
- A carrier needs the packet-filtering function itself running on the cloud, separate from the system that pushes service intent. What should be instantiated?
- A harbor leaf has used only a few hundred VLAN identifiers, yet two tenants each require VLAN 200 with overlapping addresses. How should the leaf separate them?
- A log shipper is a long-running process that must share the host kernel and be scheduled beside a virtual firewall. Which placement fits the shipper?
- A virtual firewall image and flavor already boot from the catalog, yet every new instance attaches only to a tenant data network and the orchestrator does not learn a management address. What gives the instantiated firewall its first management reachability?
- Two utility metros each reuse VLAN identifiers for different customers. Neither site is near 4094, but a bridged interconnect would merge those customers. What keeps them apart?
- An orchestrator at a transit provider already holds service intent for a new security function, but nothing in the cloud is filtering as that function. What is missing?
- A university department receives a runtime and a database from the central cloud team, deploys only its application, and never gets a guest to patch. Which model is that?
- Virtual routers are already onboarded with an image, a flavor, and day-0 reachability. The team must push one YANG service intent to every router. Which path fits?
- An orchestrator must place a single tracking process built for the host kernel, and the shipping line does not need a separate guest kernel or a strong guest boundary. What should it schedule?
- A broadband catalog already lists the virtualization program and the orchestration system, yet nothing names the component that terminates subscriber sessions and forwards their packets on cloud compute. Which component belongs on that card?
- Service intent is already in the orchestrator. The edge routers expose that YANG datastore only over SSH, with no HTTP configuration listener and no gRPC dial. How should the configuration be delivered?
- Two tenants will run untrusted packet-inspection binaries on the same hosts. Each binary is one process, and a compromise must not share a kernel with the other tenant. What should host each binary?
- A carrier runs a virtual firewall on its own cloud pool and, during hall maintenance, places that same guest on a public provider pool. The tenant still patches the guest in both places. Who operates the pools in this design?
- A design review labels a cloud-hosted virtual route reflector as the orchestration system for a mobile core. What is that reflector in the virtualized architecture?
- Tenants bring overlapping address plans, and unused 802.1Q identifiers remain well inside the usable range. One shared routing table cannot hold two copies of the same prefix. How should tenancy be separated?
- A national railway operator needs a Layer 3 VPN service definition applied across many provider edge routers. NSO maps one service definition to the device-specific configuration required on each participating router. An engineer proposes logging into one router CLI to type the config. Which action orchestrates the service intent across all devices?
- Fifty virtual provider-edge routers already forward traffic, and one QoS policy must be described once and applied to every one of them. Which component does that job?
- A hosting bridge has assigned every usable 802.1Q identifier from 1 through 4094, and the next tenant still needs isolated segments. An engineer proposes identifier 4095 on that bridge. Which design isolates the tenant?
- A city tax calculator must run on an event after each completed return upload, must not leave a guest or a standing runtime to patch, and the city will not operate the pool. The provider may reuse the execution environment between events. Which model fits?
- A prepaid rating function in a mobile core is one process that any worker with the same kernel should start, stop, and move, and that move must not wait for a guest operating system to boot. Which placement matches the requirement?
- A lawful-intercept probe ships as a kernel module that the shared host kernel will not load, and private namespaces do not give it another kernel. Which runtime should run the probe?
- A bank platform team still receives guest machines to patch. Staff operate the everyday pool, and during tax week extra guests run on a pool a public provider operates. Which description matches that arrangement?
- A regional hoster has assigned every usable 802.1Q identifier from 1 through 4094 on one bridged fabric, and the next tenant still needs its own isolated network. Which design removes that constraint?
- During a change window, utility WAN routers may be configured only through an HTTP API that carries YANG models. Which interface matches that constraint?
- A utility billing archive shares hosts with other tenants and must keep a hard guest boundary so neighbors cannot share its kernel, even though the archive uses a mainstream operating system. Which placement matches that boundary?
- County clerks open a finished land-records application in a browser. The vendor operates the guest and the runtime, and the clerks do not deploy code or patch a system. Which service model is that?
- An MVNO has many virtual routers that engineers still configure one by one. The missing piece is a system that takes one service intent and applies it across those functions. Which system is that?
- Dozens of virtual session border controllers already run on compute, and operators still type the same codec policy into each one. Which component should push that policy once?
- A virtual router at a grain elevator is already onboarded with its image, flavor, and day-0 path. The change window allows only a gRPC dial that must read and write the YANG datastore. Which interface fits?
- A port authority runs the compute pool inside its own hall and hands each terminal team a guest that the team patches. No outside operator takes a burst pool. Which model is that?
- An airport voice recorder runs only on the vendor kernel shipped with the appliance and must keep a guest boundary from other tenants on the same host. Which placement fits?
- Two customs labs are hard-coded to the same VLAN identifier and the same subnet. Free bridged identifiers from 1 through 4094 remain, yet one shared bridge would merge the labs. How should the provider isolate them?
- A radio colocation bridge has already assigned every usable 802.1Q identifier from 1 through 4094. The next station still needs isolation from the others. Where should that station be placed?
Cloud Interconnect (25%) · 75 questions
- A water utility must advertise its real plant prefixes into a cloud virtual network, and the contract forbids any path across the public internet. Segment routing already steers the provider core. Which attachment meets the requirement?
- A bank wants a dedicated path from its cage into a cloud provider and does not want reachability to depend on encryption over the public internet. Which design meets that requirement?
- A branch must reach a cloud virtual router across the public internet, and the traffic must be encrypted on that untrusted path. Which design meets the requirement?
- An operator needs a building where its backbone, a second carrier, and a cloud on-ramp meet so a cross-connect can be ordered. The building must not be treated as a cloud region. Which facility fits?
- Two inland data centers extend one tenant subnet with EVPN and VXLAN. Hosts in that subnet cannot reach each other across the sites, while underlay pings between the leaf switches still succeed. Which path element should be inspected?
- Two regional data centers extend a tenant Layer 3 service with EVPN across a segment-routing MPLS core. Routes from the far site stop arriving, but switching inside each building still works. Which path element matches?
- Two carriers need to hand traffic to each other in a building neither of them owns. Each already has a cage in that carrier-neutral facility. Which connection belongs in the design?
- A provider cage and a cloud on-ramp share a carrier-neutral building. The provider needs a local handoff into that cloud. A designer called the building itself a cloud region. Which connection should they order?
- A bank wants a dedicated path from its cage into a cloud provider, and the handoff must stay off the public internet. Encryption is not the requirement, and core traffic engineering is not the requirement. Which design fits?
- A branch aggregator reaches the provider cloud across the public internet. Policy says that path must be encrypted. A dedicated facility or a tunnel header alone must not be treated as encryption. Which design meets the policy?
- A wholesale customer has one point-to-point Ethernet service between two cities. The attachment circuits are up, but the emulated circuit between the provider edges is down. The service is a pseudowire, not an EVPN fabric. Where is the fault?
- Two leaves in a data-center fabric can ping each other across the underlay, but hosts on an extended VLAN no longer learn remote MAC addresses. The design extends those hosts with EVPN and VXLAN. Where should the operator look first?
- A game provider wants a small site near its players so session traffic avoids the long haul back to the home region. What should be added?
- A pharmacy chain reaches its cloud across the public internet and must encrypt that traffic on a path that is not private. Which addition supplies the missing protection?
- A bank wants a dedicated path into its cloud that stays off the public internet, and it does not need an encryption tunnel to make that path private. Which connection matches?
- A wholesaler connects two yards with a point-to-point emulated circuit, and that circuit drops while the EVPN overlay used by other sites stays up. Where should diagnosis start?
- Two hospital data centers extend one storage segment across an IP fabric that carries VXLAN with an EVPN control plane, and a MAC learned at one site does not appear at the other. Which fault matches the encapsulation actually in the path?
- A film studio needs a fiber cross-connect to a cloud on-ramp and another cross-connect to a second carrier inside a building where many providers already meet. What role does that building play?
- A shipyard backs up a design vault to the cloud across the public internet inside a GRE tunnel. The tunnel is up, and policy says that internet path must be encrypted. What should be added?
- An insurer's private interconnect into the cloud is up, and an IPsec overlay between the same two edges is also up. Both still cross one congested link inside the provider core. Which change can steer around that congested core link?
- A weather service wants radar uploads processed near a coastal site. A cloud-edge facility there can host the attachment. Leaders want to call that building the home region. What should be deployed?
- In a sports arena, leaf-to-leaf pings succeed and the VXLAN tunnels are up, but a scoreboard shows up in the wrong tenant. The fabric extends tenants with EVPN and VXLAN. Where is the fault?
- A cannery already reaches the cloud on a trusted private interconnect. The new need is to steer one batch transfer onto a specific path in the MPLS provider core. What meets that need?
- A courthouse point-to-point Ethernet service drops frames in one direction while the attachment routers still ping. This circuit has no overlay, and a separate office EVPN fabric is healthy. The provider provisions this Ethernet service using a pseudowire. Where should the operator look?
- Two retail data centers extend Layer 2 with EVPN and VXLAN across the fabric. A MAC that should be learned on that overlay is missing. The core is not segment-routed, and there is no point-to-point wire. Where is the fault?
- A water utility connects two plants only inside an ACI fabric. Endpoints sit in the correct groups, the contract permits the port, and the packet still drops across leaves. Where is the fault?
- A game network wants player traffic to enter the cloud close to the players, on a short path, from a site built for that edge role. A downtown meet-me room is not the goal. What should they use?
- A regional clinic reaches its public cloud over the commodity internet and must encrypt that untrusted hop. The clinic has no dedicated cloud circuit. What meets the encryption requirement?
- A manufacturer must steer a flow across the provider core on a chosen low-delay path. The payload stays on that private core and does not need encryption. What provides the steering?
- A university needs a fiber meeting with a second carrier inside a building where many providers already have cages. The building is not a cloud region. What should the university order?
- A bank must enter its public cloud on a dedicated private path from a meet-me room, and encryption is not the requirement. Which attachment provides that private path?
- A regional internet provider needs a private handoff to a national carrier that already has a cage in the same carrier-neutral building. Which connection belongs in that building?
- A pharmacy chain reaches its public cloud across the internet and must encrypt that traffic on a path that is not private. Which design adds the encryption?
- Two data centers are joined by one point-to-point Layer 2 circuit that is down, while the IP core and the fabric overlays stay healthy. The provider provisions this Ethernet service using a pseudowire. Which encapsulation is actually in the failed path?
- A point-to-point Layer 2 circuit between two factories is down. The path is a pseudowire, not an EVPN overlay, and neither site uses an ACI fabric or a segment-routed core. What failed?
- Two hospital buildings extend a tenant with EVPN and VXLAN. Underlay pings between the tunnel endpoints succeed, and the far building's EVPN route is in the local BGP table. Frames for that tenant still do not forward, and the local tunnel endpoint has no configuration for this tenant's VXLAN identifier. Where is the fault?
- A studio in a carrier-neutral building needs a fiber cross-connect from its cage to a second carrier in that same building. Which connection is that?
- A game platform wants user traffic to reach cloud resources inside a carrier-neutral building instead of hauling every session to a distant region. Which design fits?
- A hospital forbids the internet as the path into its cloud and wants a dedicated attach, with no request to encrypt an untrusted path. Which design fits?
- A bank already uses a private interconnect into the cloud on-ramp, and the new requirement is to steer that traffic across the provider core. Which design meets the steering requirement?
- EVPN routes for a data-center interconnect are present, but the segment-routing transport that should carry them between the sites is down. Which fault is that?
- Inside one leaf-spine fabric, hosts on different racks lose Layer 2 reachability. The fabric extends those segments with EVPN and VXLAN, and a separate branch pseudowire is up. Where is the fault?
- A mobile operator must hand traffic to a second carrier whose routers sit in another cage of the same neutral building. Which connection belongs in that building?
- Two retail data centers extend EVPN across a segment-routed core, and the failure is on that core rather than inside either fabric. Which encapsulation is in the failing path?
- A factory runs a single ACI fabric. A contract already permits one pair of endpoint groups inside the first VRF. The devices that fail are in two different VRFs, and no route is shared between those VRFs. Underlay ports are up. Where is the fault?
- Two small sites are joined only by an Ethernet service. The provider provisions this Ethernet service using a pseudowire. This service uses a point-to-point pseudowire. Hosts on that emulation can no longer reach each other. Which fault matches the path?
- A freight exchange already has a private interconnect into the cloud across a provider core. The new need is to steer flows onto one low-delay core path. What meets that need?
- A payroll bureau already encrypts its cloud path with IPsec across the public internet, but a network policy prohibiting public-internet transit forbids that internet crossing. What meets the rule?
- A hospital already sends imaging traffic over a provider MPLS VPN. The new contract says the payload must be encrypted on that path, not merely separated by the provider. What should be added?
- A clinic already uses a dedicated private interconnect into the cloud and then finds the fiber has no cipher. Confidentiality on that path is the new requirement. What adds it?
- A studio in a carrier-neutral building already uses a cloud on-ramp. It now needs a private fiber handoff to a second carrier cage in the same meet-me room. Which connection meets that handoff?
- Players in one metro reach a distant cloud region by hairpinning across the country. A carrier-neutral building in that metro can host a closer cloud termination. What should the design add?
- Inside one factory ACI fabric, endpoints that policy should permit cannot reach each other. The path has no data-center interconnect overlay and no pseudowire. Where does the fault belong?
- Each data center extends local segments with VXLAN, and EVPN between the sites rides a segment-routed MPLS core. Local tunnel endpoints still ping inside one site, but routes to the other site vanish when a core path fails. Where is the fault?
- Airline crew apps in one city hairpin through a carrier-neutral building across the country, where their only cloud cross-connect sits. A cloud-edge facility is already in their city. Which attachment shortens the path?
- A regional fiber provider and a national carrier already lease cages in the same carrier-neutral building and need to hand off a wavelength there. Which connection meets that handoff?
- A grocery chain already enters the cloud on a private interconnect, and its backup crosses the public internet and must be encrypted. The provider core does not need a new steering policy. Which design encrypts the backup?
- A clinic can reach its cloud virtual router only across the public internet, and patient records on that path must be encrypted. The provider's segment-routed core serves other sites and has no port into this cloud. Which design meets the requirement?
- The only circuit between two warehouse data centers is one point-to-point Layer-2 emulation, and that emulation is down. No fabric overlay, segment-routed core, or policy fabric carries this circuit. Which repair matches the path?
- Cloud on-ramp traffic must follow a low-latency provider core path and fail onto a second engineered path. Encryption is already handled elsewhere. What steers those core paths?
- A trading archive must reach its cloud on a dedicated port that does not cross the internet. Core steering already works, and encryption of an internet path is not the request. Which attachment fits?
- A video provider's packets are already on the carrier core, and the carrier must steer them onto one chosen path. Encryption is not the requirement. Which design matches the steering need?
- Two rail yards are joined only by a pseudowire. Signaling for that pseudowire is up, small frames cross, and large frames are dropped. A separate EVPN service between other sites is healthy. What explains the large-frame drops?
- A sports broadcaster must encode video beside the venue interconnect so the path into the cloud stays short, instead of hauling raw video to a distant region first. Which facility matches that need?
- Inside one ACI fabric, two endpoint groups have learned each other's endpoints, but application traffic between them is dropped. No pseudowire and no segment-routed core are on this path. The EPGs are in a policy-enforcing VRF, and no contract allows the required flow between them. Which fault fits?
- Two retail data centers advertise MAC addresses with EVPN, the core under that EVPN is segment routing with MPLS, and forwarding fails because the core label stack is wrong while the EVPN routes still exist at the edges. Which path is at fault?
- A telescope archive has its private interconnect down for maintenance, and the only backup into the cloud is the public internet. The archive still requires encryption on that backup. What should be added?
- Ship telemetry hairpins through a distant cloud region before anyone can process it. A carrier-neutral shipyard already hosts interconnects. Which addition shortens that path without becoming the home region?
- In a carrier-neutral building, three access networks are already on the local internet exchange. A regional provider wants to exchange routes with those three and does not want transit or a cloud port. Which arrangement matches?
- A clinic sends records to a cloud firewall across the public Internet, and the records must be encrypted on that untrusted path. No dedicated cloud interconnect is in place. Which design adds the encryption?
- A stock exchange keeps a single point-to-point Layer 2 circuit between two ports. One attachment circuit is down, and the path contains no EVPN, no VXLAN, and no ACI fabric. Which fault matches the path?
- A power-grid control center runs an ACI fabric. A contract already permits the relay flow, the underlay is up, and the leaf has no forwarding entry for the relay controller. Where is the fault?
- A seed vault already reaches the cloud on a private interconnect that stays in service. An auditor requires the vault records to be encrypted on that same path. What should be added?
- Two cache operators lease cages in the same carrier-neutral building and must exchange fill traffic there. Neither side needs a new cloud region. Which connection completes the exchange?
- Two canyon weather stations extend one VLAN with EVPN and VXLAN. The underlay between the leaves still pings, and one leaf never learns remote MAC addresses for that VNI. Where should the operator look?
High Availability (20%) · 60 questions
- A tenant needs its own subnets and a controlled path out of the cloud, separate from other tenants and from the provider underlay. Which construct fits?
- A cloud fabric peers BGP with three provider edges that advertise one destination at equal preference. Traffic for that destination should use all three exits. The three BGP paths meet the platform’s multipath eligibility rules, and the forwarding platform supports at least three paths. Which forwarding design fits?
- Users of a clinic portal cannot connect after one load-balancer node stops responding. Name resolution still returns the site address, and the route to the site remains installed. Which resilience model matches the failure?
- The cloud fabric already speaks OSPF to two physical routers. Both links have equal cost, but traffic uses only one next hop. The operator wants both next hops used. Which change fits this fabric?
- Subscribers reach a virtual packet gateway through a load balancer. After one balancer node froze, traffic kept hashing to it and sessions stalled. DNS and the BGP next hops toward the site stayed healthy. Which change matches the failure?
- A tenant in a provider cloud needs its own subnets, its own route table, and a controlled path out to its VPNs. The tenant must not share one broadcast domain with other customers. Which construct is that?
- A clinic virtual firewall must stay reachable if one upstream provider fails completely. The two attachments must not share one upstream router. Which design fits?
- A customer router must dual-home to two provider edges as one logical Ethernet bundle so either edge can fail without creating a loop. Which design fits?
- A virtual broadband gateway keeps its control process in one VIM. The operator wants a standby for that process if the active process fails, on a different compute host, without moving the service to a second cloud. Which placement meets that requirement?
- A clinic virtual firewall has two uplinks that both end on one provider edge and share that edge upstream. How should the attachment change so one provider failure does not isolate the firewall?
- A rail cloud separates its VIM controller/API services from forwarding nodes. Existing flows require no controller exchange during the planned active-to-standby handoff, and forwarding nodes remain healthy. What does that controller failover cover?
- A regional hospital network connects its imaging archive to a service-provider cloud fabric over two equal-cost uplinks and must keep both next hops active for resilience. Both uplinks advertise the same destination through BGP, and their paths satisfy this router’s multipath eligibility rules. Which design keeps more than one next hop alive?
- Traffic from a cloud fabric toward the physical network should keep several equal-cost next hops in service at the same time. The physical routers advertise the destination through BGP, and their paths meet the platform’s multipath eligibility rules. Which design provides those next hops?
- A packet-core control process needs a hot standby in the same cloud so a control failure is covered without a second unrelated cloud. Which placement matches that control-plane requirement?
- Name lookups for a clinic cloud stop after its only recursive resolver fails, while existing routes and application health checks stay intact. Which resilience matches the component that failed?
- Harbor grain-terminal clients use only one resolver, and that resolver has stopped. Application routes are present and both load-balancer nodes pass health checks. What covers this failure?
- A botanical garden router is cabled to two provider edges. Both links forward and a loop has formed. The garden wants one Ethernet bundle so either edge can fail without a loop. What design fits?
- A ferry terminal connects to two provider edges in the same hut, and both edges reach the core through one shared fiber splice. A cut at that splice isolates the terminal. Why does this dual-homed design fail to survive the splice cut?
- A cloud fabric facing a mint runs IS-IS. Two paths have equal cost, yet the edge installs only one next hop. What should the edge install?
- A marina virtual broadband gateway holds two provider sessions, and both leave through one virtual NIC on one compute host. A host failure drops both sessions. What makes this attachment multi-homed?
- A conference provider runs one virtual session border controller on a single compute host. Maintenance of that host removes the service. Links on the host are already duplicated. What placement fixes the host fault?
- A virtual CGNAT function loses all forwarding when its only compute host fails. The control standby in the same VIM stays up and still has nothing to forward. What should be added?
- A credit-union firewall has two circuits that both fail when one upstream carrier has an outage. One provider failure must leave another provider in service. What attachment meets that goal?
- A credit union is moving teller applications into a public cloud and needs its own subnets, route tables, and a controlled path back to the branches. Which construct is that tenant network?
- A regional bank must keep its payment-verification VNF online if any single provider or access device fails. What design fits that requirement?
- A video platform already peers BGP from its cloud edge to three provider routers over equal-cost links and needs all three next hops used for forwarding. The three BGP paths meet the platform’s multipath eligibility rules, and the forwarding platform supports at least three paths. Which design installs more than one next hop?
- At a stadium, name lookups fail while the next hop still forwards and the application load balancer still passes health checks. A second resolver is idle. What should take the lookups?
- A virtual router in one cloud drops traffic when its compute host or its top-of-rack switch fails, even though its control process already has a standby. Which addition covers the data plane?
- A factory virtual firewall must keep working if one upstream provider fails. Both current links ride the same metro fiber into that one carrier. Which change is real multi-homing?
- Two application teams each have a virtual private cloud and need a controlled path between them without joining the provider underlay. Which design fits?
- Two equal-cost uplinks from a cloud fabric already sit in one OSPF area, and both next hops must stay in use. Which forwarding design fits?
- A university research lab needs its own isolated network inside a service-provider cloud, with private subnets for compute and storage plus a single controlled path to the Internet, separate from the provider transport. What provides that tenant space?
- A video portal still resolves in DNS and the load balancer marks both nodes healthy, yet sessions fail when the only route toward the fabric withdraws. Which resilience matches that failure?
- A virtual firewall has two uplinks that both terminate on the same provider edge router. Which change actually multi-homes it?
- Resolvers answer and the routes stay up, yet a ticket-seller load balancer keeps sending new sessions to a silent pool member while another member is healthy. What should change?
- A university research portal hosted in a service-provider cloud must keep resolving names when one DNS server fails. The sites already have two routing next hops, yet an outage of the single configured resolver still stops logins. Which design fits?
- A studio edge has two equal-cost paths installed toward the cloud. One large transfer fills only one path, the other path stays nearly idle, and smaller flows use both paths. What explains the one-sided transfer?
- A cloud edge learns two equal-cost OSPF paths toward the physical network and still forwards on only one next hop. How should both paths carry traffic?
- An airport firewall sends all traffic to one provider and uses a second provider only after the first withdraws its routes. The providers do not share an upstream failure. A reviewer says this is not multi-homing because traffic is not split. What is the right conclusion?
- A clinic buys two carrier circuits for a virtual router, but both enter through one building riser and both terminate on one upstream router. What attachment survives a failure of that shared router?
- A mobile-core cloud already runs an active controller and a standby controller in the same VIM. User traffic still stops when the single packet-gateway forwarding process crashes. What does the controller pair leave uncovered?
- A museum moved its portal to a new address. The resolver now answers with that new address, the route to it is installed, and the load balancer there is healthy. Some clients still open the retired address. What failure mode is this?
- A regional hospital runs its patient portal on backend servers in two data centers behind a service-provider load balancer. One server must be able to fail so new requests can be directed automatically to the surviving backend after failure detection, with the balancer detecting the failure automatically. What fits?
- A concert-venue firewall is dual-homed with EVPN link aggregation. The bundle is up and both provider edges are forwarding. The firewall receives two copies of each broadcast. What is missing?
- Clients resolve the service name, the load balancer answers, and its health checks pass. Return traffic from the balancer stops when one uplink fails, because that uplink is the only next hop. What resilience is missing?
- A virtual CGNAT control process already has a standby on another compute in the same cloud, yet packets died when the only top-of-rack in the data path failed. Which addition covers that failure?
- A power-utility cloud fabric learns two equal-cost OSPF paths toward campus and forwards on only one of them. BGP is not running on those adjacencies. Which change gives equal-cost multipath?
- Both uplinks of a ferry-terminal virtual firewall are pinned to the same leaf, so a reload of that leaf drops every session. A second carrier name would still land on that leaf. Which change is real multi-homing?
- A port-authority portal name resolves from both resolvers, and both load-balancer nodes pass health checks, but the only route to the service prefix has withdrawn. Which fix matches the failed component?
- A regional bank uses a provider-hosted virtual firewall with two instances for continuity, but both instances went down when one compute host failed. The two instances already have supported automatic firewall failover, the required state handling, and independent usable network paths. Which scheduler placement policy removes their shared compute-host failure?
- A Cisco IOS XR cloud edge uses ordinary equal-cost BGP multipath with a path limit greater than one and no unequal-cost or IGP-metric-ignore feature. All other multipath eligibility checks pass for two paths to one prefix, but one BGP next hop has a higher IGP metric. Only one path is installed. Why is the second path left out?
- A harbor crane cloud fabric runs IS-IS toward two physical routers at equal cost, yet forwarding uses only one next hop. Which change keeps both next hops alive?
- A hospital virtual firewall has two uplinks, and both of them terminate on the same provider edge router, so a reboot of that router isolates the firewall. Which change removes that shared failure?
- A warehouse firewall must dual-home to two provider edges so one edge can fail, and the two links must behave as one bundle without a forwarding loop. Which design matches that requirement?
- A winery tenant wants guest devices isolated from the production cellar network, with their own subnets and a controlled exit. Which design supplies that isolation?
- A retail checkout name resolves to the live site, and the load balancer at the live site is healthy. Traffic still arrives at a failed site because a more-specific route to the failed site is preferred over the aggregate that covers the live site. Which failure mode is this?
- Shoppers resolve the store name, and the route to the checkout site is up, but one load-balancer node is dead and still receives new sessions. Which fix matches the component that failed?
- A ski resort firewall has two fibers, and both fibers terminate on the same provider router in the village hut. One router failure still isolates the resort. Which change is real multi-homing?
- A rural clinic network must stay reachable if its primary upstream route fails, and adding name servers alone will not fix a lost route. Which design provides routing redundancy?
- A stadium ticket site resolves to the right address, the route is correct, and both load-balancer members pass health checks. Every spectator arrives from one shared address, and source affinity sends all of them to one member until that member overloads. What failure mode is this?
Security (15%) · 45 questions
- Every call that creates a VNF must prove the identity of both the orchestration client and the VIM API. Which control meets that requirement?
- A stadium edge router forwards visitor traffic normally, but SSH and BGP to the router itself stall while a burst of packets is aimed at the router's own addresses. Which control protects the router without filtering that transit?
- Tenant guests resolve names through a shared recursive resolver, and the operator must flag queries for malicious domains. Guest disks are out of scope. Which service fits?
- A volumetric flood targets one customer prefix. Every packet toward that prefix may be discarded, and every other customer prefix must stay reachable. Cleaning the good packets is not required. The response must discard all traffic to the attacked prefix using a BGP-triggered discard route, without traffic diversion or a signature match. Which action fits?
- Tenant guests in a virtualized infrastructure can open sessions to the cloud controller API. The operator wants those workloads unable to reach the control and management plane. Which change matches the requirement?
- Tenant guests in an insurance cloud cannot route to the VIM API. A build job presents a valid certificate and a valid token, then deletes another tenant's network. The token's role is admin for the whole cloud. What must change?
- A regional university hosts admissions and online learning portals in its campus data center. A DoS flood targets one web service with high-rate UDP packets to a single destination port, while other services using the same server prefix must stay reachable. Operators need to stop only the attack flow at provider edges with minimal collateral impact. The affected edges have supported FlowSpec filtering and enough remaining ingress capacity. Which control matches the requirement?
- A volumetric flood targets one customer prefix. Edge filters cannot absorb the volume, and legitimate packets to that prefix must still be delivered. The rest of the provider must stay up. Which mitigation fits?
- Tenants in a public cloud resolve names through the provider recursive DNS. The security team must see lookups for a known malware domain and has no access to tenant guest disks. Which service can see those lookups?
- A transit router accepts many prefixes from a customer, including prefixes the contract does not allow that customer to advertise. What control limits the accepted prefixes?
- The service orchestrator and the cloud API must each prove its identity before either side accepts the session. Which control matches that mutual proof?
- An archive guest stores infected files. Recursive queries from that guest look ordinary, and the live flow shows no exploit. Where should detection be placed?
- A library automation account calls the cloud API with an empty credential and the change still lands. The channel already verifies the server. Guests cannot reach the management plane. A request with no API token, client certificate, or other client authentication succeeds. What is missing?
- A volumetric flood with a clear signature targets one customer prefix at a cloud edge, and that prefix must stay reachable while the attack packets are dropped at the edge. Which mitigation matches?
- A school cloud must inspect recursive queries for tunneling behavior and for lookups of known malicious names. Which service is in a position to see that traffic?
- A school district must inspect recursive DNS queries for newly registered domains used by phishing. Disk scans and other flow inspection do not see those queries. What should be added?
- Two routers in a meet-me room share one Ethernet segment, and the operator must encrypt the frames on that hop. Which control matches the hop?
- An orchestrator must prove its identity to the VIM, and the VIM must prove its identity back, on the API channel used to manage tenant functions. What protects that exchange?
- Two routers in a shared cage are connected by one Ethernet hop, and that hop must be encrypted. Device logins and packet filters are already in place. What protects the hop?
- A volumetric flood matches a known signature toward one hosted game prefix. Legitimate players on that prefix must stay reachable, and other customers must be untouched. What should the provider distribute?
- A hosting provider sees a volumetric flood toward one customer prefix while every other customer on those routers stays healthy. Divert the targeted prefix to a scrubbing service with enough capacity and reinject permitted traffic. Test convergence and existing-session behavior; diversion does not guarantee zero interruption. Which response limits blast radius to the attacked prefix while preserving legitimate sessions where possible without discarding the other customers?
- The orchestrator calls the cloud API over TLS, but only the server presents a certificate and the client is not proven. Which change fits?
- The exposure is the Ethernet hop between a top-of-rack switch and a compute host, and that hop must be encrypted. Which control fits?
- An orchestrator calls a VIM API, and the design must prove both the calling client and the API server on that call. Which control proves both parties?
- An allowed application flow is exploiting a container, and DNS queries from that container look ordinary. Where should exploit detection sit?
- A flood is one UDP signature aimed at a customer prefix, and other flows to that prefix must stay up. Which mitigation drops only the signature?
- A university security team must watch recursive DNS queries for a tunneling domain, so the control has to see the questions themselves. Which placement can see those queries?
- Fiber from a top-of-rack switch to a virtual firewall host crosses a shared cage, and the frames on that Ethernet hop must be encrypted. Neighboring tenants can see the strand. What control matches the hop?
- A hospital portal is under a volumetric flood from one known source prefix. The portal prefix must stay reachable, and every provider edge should drop that source. Which control matches?
- Carrier routers still accept one shared local password for operator login, and the team needs per-user authentication plus command accounting. What should they deploy?
- One off-net host sprays a short-packet flood at many customer prefixes. Those prefixes must stay reachable, and every edge should drop that source. Which mitigation matches that blast radius?
- One amplification signature is flooding a single hosted name, other services on that prefix must stay up, and the prefix must remain on its current path. What should the provider install?
- DNS queries from a brokerage workload look clean, but exploit attempts appear only on the east-west flow between two guests. Which service can see that activity?
- Two tenants' virtual firewalls can already reach each other's day-0 management addresses, while orchestrator API calls require authentication and the API channel is encrypted. Which control closes that reachability?
- A large hospital system hosts its patient portal on a single public prefix. During a volumetric DDoS, edge links fill with traffic toward that portal prefix and the core is at risk. The hospital accepts loss of all traffic to the victim prefix. Operators require a BGP-triggered destination discard across participating provider edges. Which control drops the attack traffic toward a victim prefix at the provider edge?
- A transit provider's automation script creates networks by calling the VIM API, and both the script and the API must prove their identities before any call is accepted. Which control matches that requirement?
- Guests query a recursive resolver for command-and-control names. The security team must see those queried names. The lookups do not leave a file on disk. Where should this control sit?
- A known remote-code pattern arrives as HTTP at a transit-agency virtual load balancer. DNS queries look ordinary, and disk scans of an image library never see this live flow. Where should detection sit?
- Edge routers can already drop one attack pattern aimed at a game-download prefix, and every other packet to that prefix must stay on the current path. Which mitigation fits that blast radius?
- A casino tenant guest can open the cloud controller API on the management network. API credentials already exist. What must change so tenant workloads cannot reach that plane?
- Customers of a water utility transit router can send packets to the router loopback, while ordinary transit must still be forwarded. Which control stops packets aimed at the router?
- A utility cloud's Windows management VM runs a PowerShell process covered by its enabled host exploit-protection engine. A memory-injection attack targets that process, with no file written and no DNS query. Where should detection for this attack be placed?
- A charity telethon prefix is under a volumetric flood, and good sessions toward that same prefix must survive. Which mitigation keeps the good traffic?
- A game host on one customer address is hit by a UDP flood with expressible header fields, such as destination prefix, protocol, ports, or packet length. The link still has spare capacity, legitimate sessions to that host must continue, and every edge must drop only that flood. Which response matches the blast radius?
- A transit customer portal is receiving a known exploit pattern inside HTTP requests to the web virtual firewall. Which service can see that attack?
Service Assurance and Optimization (15%) · 45 questions
- Operators already collect flow records and router logs for the core. They need an active measurement of delay for a single SR policy. Which addition matches that measurement?
- A cloud-edge router should push interface counters to the assurance platform continuously. The team does not want a management station to poll the router on a timer. Which collection method matches that requirement?
- One tenant virtual firewall is unreachable. The VIM API still creates other instances, the compute host is up, and storage volumes still attach. The firewall’s console confirms its forwarding process has stopped and the vNIC path was verified independently. Which fault matches the evidence?
- A retail chain's cloud-controller API answers inside its target time, yet one virtual firewall misses its session-setup target. What does the healthy API-time figure evidence?
- Backbone engineers want supported interface operational-state leaves, such as link state, pushed as those values change from cloud virtual routers, rather than collected by a periodic poll. Which mechanism matches that requirement?
- A utility needs an immediate notice when a router power supply fails. Flow records and a slow counter poll are already collected. The notice must be an event from the router, not a reading from inside a guest. Which method matches?
- A retail virtual firewall's process table is stuck and its local filesystem is full. Routers and the host do not export those guest-internal readings, and router interface counters look normal. Which collector can see the process and filesystem state?
- A virtual probe must forward a very high packet rate and must skip the software switch on the compute host. Which design matches that forwarding requirement?
- One tenant guest is down, while its compute host stays up, its storage stays reachable, and the infrastructure API still serves other tenants. What failed?
- One tenant guest is stopped. Other guests on the same compute host still answer, their storage volumes are healthy, and the VIM API accepts calls. Which fault matches that evidence?
- An assurance desk wants interface counters from the provider fabric pushed continuously instead of collected by a periodic poll. Which method matches that collection model?
- Operators need records of which addresses communicated, on which ports, and how much traffic passed, exported from the cloud-edge routers. Which telemetry supplies those records?
- A virtual inspection guest must raise its packet rate. Profiles show the guest kernel network stack is the bottleneck, and the host software switch is not saturated. What change fits?
- Operators want interface counters from cloud routers pushed continuously, rather than pulled on a timer. The cloud controller and the service catalog are not the target. What should they enable?
- In a mapping lab, every guest on one compute host is down. Guests on other hosts still run, storage volumes still attach, and the VIM API answers. Host health and hypervisor logs confirm the compute host stopped running its guests. What fault is this?
- A port authority must show whether its virtual firewall is meeting an agreed session-setup objective. Host CPU averages and completed order counts are already on display. Which figure is evidence of that objective?
- A broadcaster must measure delay and loss on a segment-routed path between two studios. Flow records and device logs are already collected. What matches this path measurement?
- Service orders for a touring orchestra stay unfulfilled. The virtual router CPU is idle, and the cloud controller API answers quickly. Which view should operations read?
- A virtual router must forward at a high packet rate, and the guest must receive frames on a virtual function of the physical NIC so the software switch is skipped. Which acceleration matches?
- One virtual probe is down. Other guests on the same compute host are healthy, the VIM API answers, and storage volumes attach normally. What failed?
- One tenant virtual firewall is stopped. The VIM API still creates other instances, the compute host is up, and storage volumes still attach. Which fault matches that evidence?
- At a hosted studio cloud, every guest on one hypervisor misses its forwarding deadline. Guests on the other hypervisors are fine, disk reads succeed, and the API still lists that hypervisor as up. The affected host has sustained CPU saturation and elevated guest CPU scheduling wait; storage latency, NIC queues and packet-path counters are normal. Which layer is at fault?
- A supported Cisco Nexus switch drops packets during short egress-queue bursts between counter polls. It supports hardware microburst detection with threshold-triggered event records, but that feature is disabled and no queue events are logged. Which method can capture the bursts the polls miss?
- A packet-core team wants interface counters pushed continuously from the routers instead of pulled on a slow interval. Which method matches that continuous push?
- A clinic virtual firewall stays in the ACTIVE state, its system disk still shows reads and writes, and other guests on the same host are healthy. The firewall's management port is closed and its process list no longer shows the firewall process. Which fault is this?
- New instances fail because their image volume cannot be read, while compute hosts answer, the VIM API is healthy, and a running guest stays up. Which fault is that?
- Flow records already show volume on a video network segment-routed core, but not whether one path missed its delay target. What measures that path?
- A virtual router at a packet fabric forwards in the kernel, and that kernel path stalls at the required packet rate while the software switch toward the guest does not. What should take over forwarding?
- Instance scheduling stalls and the research-cloud API times out, while the request never reaches a running guest. Which view explains the stall?
- The cloud controller API is slow to answer while a sample guest looks idle. Which view shows whether the controller is the problem?
- Creating a port in the cloud has become slow. A running virtual firewall stays idle, and its streamed counters stay quiet. Which assurance view should be read for this slowdown?
- A new virtual probe stays in an error state because its volume will not attach. Other guests on the same compute host keep running, and the infrastructure API still answers. The block-storage backend logs an explicit attach failure for the requested boot volume. Which fault domain is this?
- Transcoder instances on many different computes all stall on disk reads at the same moment, those computes still answer, and the cloud API can still list and start instances. Where is the fault?
- In a university research cloud, traffic still passes through virtual routers that are already running, and their volumes still read and write. Every new call to list flavors or create a port returns an error. Which layer has failed?
- After a peering cutover, one shared edge router is congested. Operations must learn which tenant conversations filled that router, not the delay of a core path. Which record should the router export?
- A packet-capture probe guest must take a very high frame rate, and the host software switch drops frames before they reach the guest. The probe is not the fabric forwarder. The NIC and hypervisor support SR-IOV, and the traffic to capture can be delivered directly to the probe’s VF. What removes that drop?
- A mobile packet gateway already receives frames on an SR-IOV virtual function, so the host software switch is not on the path. The guest still handles every packet through the kernel network stack and cannot keep the rate. The application stays. The gateway supports a DPDK packet-I/O mode, and its assigned VF has a compatible poll-mode driver. Which change addresses the remaining limit?
- A film studio's orchestration board shows every virtual-firewall order completed, while users still report failed inspection sessions on the firewall that is already running. What does the completed-order figure evidence?
- A syslog collector guest on an NFV host emits only a few messages each second and has no packet-rate target. Which data path matches that guest?
- Live broadband gateways keep forwarding, the compute hosts answer, and the VIM API answers, but every new volume attach fails with a storage-backend error. Which fault matches the evidence?
- A regional cloud controller answers slowly. Guest CPUs are idle, and the MANO view still shows the service as deployed. Which indicators explain the slow controller?
- Creating a port through the payments cloud API has become slow, while guest CPUs stay idle and the virtual firewall keeps forwarding. Which view shows that slowdown?
- Several packet-gateway guests on one ferry compute host drop together when that host loses power. Guests on other hosts stay up, volumes stay readable, and the cloud API still accepts calls. Which fault is this?
- A museum virtual firewall looks healthy on the management and orchestration view, and the cloud controller is fast. The open question is how many sessions that firewall drops. Which indicators should be read?
- A cement plant router rebooted overnight. Flow records and path delay look normal, and the operator needs the reboot text and the process restarts. Which record supplies them?
These questions are original practice material and are NOT actual exam questions or brain-dump content. Cisco and related marks are trademarks of their respective owners. This material is not affiliated with, endorsed by, or sponsored by Cisco.