- A water utility must advertise its real plant prefixes into a cloud virtual network, and the contract forbids any path across the public internet. Segment routing already steers the provider core. Which attachment meets the requirement?
- A bank wants a dedicated path from its cage into a cloud provider and does not want reachability to depend on encryption over the public internet. Which design meets that requirement?
- A branch must reach a cloud virtual router across the public internet, and the traffic must be encrypted on that untrusted path. Which design meets the requirement?
- An operator needs a building where its backbone, a second carrier, and a cloud on-ramp meet so a cross-connect can be ordered. The building must not be treated as a cloud region. Which facility fits?
- Two inland data centers extend one tenant subnet with EVPN and VXLAN. Hosts in that subnet cannot reach each other across the sites, while underlay pings between the leaf switches still succeed. Which path element should be inspected?
- Two regional data centers extend a tenant Layer 3 service with EVPN across a segment-routing MPLS core. Routes from the far site stop arriving, but switching inside each building still works. Which path element matches?
- Two carriers need to hand traffic to each other in a building neither of them owns. Each already has a cage in that carrier-neutral facility. Which connection belongs in the design?
- A provider cage and a cloud on-ramp share a carrier-neutral building. The provider needs a local handoff into that cloud. A designer called the building itself a cloud region. Which connection should they order?
- A bank wants a dedicated path from its cage into a cloud provider, and the handoff must stay off the public internet. Encryption is not the requirement, and core traffic engineering is not the requirement. Which design fits?
- A branch aggregator reaches the provider cloud across the public internet. Policy says that path must be encrypted. A dedicated facility or a tunnel header alone must not be treated as encryption. Which design meets the policy?
- A wholesale customer has one point-to-point Ethernet service between two cities. The attachment circuits are up, but the emulated circuit between the provider edges is down. The service is a pseudowire, not an EVPN fabric. Where is the fault?
- Two leaves in a data-center fabric can ping each other across the underlay, but hosts on an extended VLAN no longer learn remote MAC addresses. The design extends those hosts with EVPN and VXLAN. Where should the operator look first?
- A game provider wants a small site near its players so session traffic avoids the long haul back to the home region. What should be added?
- A pharmacy chain reaches its cloud across the public internet and must encrypt that traffic on a path that is not private. Which addition supplies the missing protection?
- A bank wants a dedicated path into its cloud that stays off the public internet, and it does not need an encryption tunnel to make that path private. Which connection matches?
- A wholesaler connects two yards with a point-to-point emulated circuit, and that circuit drops while the EVPN overlay used by other sites stays up. Where should diagnosis start?
- Two hospital data centers extend one storage segment across an IP fabric that carries VXLAN with an EVPN control plane, and a MAC learned at one site does not appear at the other. Which fault matches the encapsulation actually in the path?
- A film studio needs a fiber cross-connect to a cloud on-ramp and another cross-connect to a second carrier inside a building where many providers already meet. What role does that building play?
- A shipyard backs up a design vault to the cloud across the public internet inside a GRE tunnel. The tunnel is up, and policy says that internet path must be encrypted. What should be added?
- An insurer's private interconnect into the cloud is up, and an IPsec overlay between the same two edges is also up. Both still cross one congested link inside the provider core. Which change can steer around that congested core link?
- A weather service wants radar uploads processed near a coastal site. A cloud-edge facility there can host the attachment. Leaders want to call that building the home region. What should be deployed?
- In a sports arena, leaf-to-leaf pings succeed and the VXLAN tunnels are up, but a scoreboard shows up in the wrong tenant. The fabric extends tenants with EVPN and VXLAN. Where is the fault?
- A cannery already reaches the cloud on a trusted private interconnect. The new need is to steer one batch transfer onto a specific path in the MPLS provider core. What meets that need?
- A courthouse point-to-point Ethernet service drops frames in one direction while the attachment routers still ping. This circuit has no overlay, and a separate office EVPN fabric is healthy. The provider provisions this Ethernet service using a pseudowire. Where should the operator look?
- Two retail data centers extend Layer 2 with EVPN and VXLAN across the fabric. A MAC that should be learned on that overlay is missing. The core is not segment-routed, and there is no point-to-point wire. Where is the fault?
- A water utility connects two plants only inside an ACI fabric. Endpoints sit in the correct groups, the contract permits the port, and the packet still drops across leaves. Where is the fault?
- A game network wants player traffic to enter the cloud close to the players, on a short path, from a site built for that edge role. A downtown meet-me room is not the goal. What should they use?
- A regional clinic reaches its public cloud over the commodity internet and must encrypt that untrusted hop. The clinic has no dedicated cloud circuit. What meets the encryption requirement?
- A manufacturer must steer a flow across the provider core on a chosen low-delay path. The payload stays on that private core and does not need encryption. What provides the steering?
- A university needs a fiber meeting with a second carrier inside a building where many providers already have cages. The building is not a cloud region. What should the university order?
- A bank must enter its public cloud on a dedicated private path from a meet-me room, and encryption is not the requirement. Which attachment provides that private path?
- A regional internet provider needs a private handoff to a national carrier that already has a cage in the same carrier-neutral building. Which connection belongs in that building?
- A pharmacy chain reaches its public cloud across the internet and must encrypt that traffic on a path that is not private. Which design adds the encryption?
- Two data centers are joined by one point-to-point Layer 2 circuit that is down, while the IP core and the fabric overlays stay healthy. The provider provisions this Ethernet service using a pseudowire. Which encapsulation is actually in the failed path?
- A point-to-point Layer 2 circuit between two factories is down. The path is a pseudowire, not an EVPN overlay, and neither site uses an ACI fabric or a segment-routed core. What failed?
- Two hospital buildings extend a tenant with EVPN and VXLAN. Underlay pings between the tunnel endpoints succeed, and the far building's EVPN route is in the local BGP table. Frames for that tenant still do not forward, and the local tunnel endpoint has no configuration for this tenant's VXLAN identifier. Where is the fault?
- A studio in a carrier-neutral building needs a fiber cross-connect from its cage to a second carrier in that same building. Which connection is that?
- A game platform wants user traffic to reach cloud resources inside a carrier-neutral building instead of hauling every session to a distant region. Which design fits?
- A hospital forbids the internet as the path into its cloud and wants a dedicated attach, with no request to encrypt an untrusted path. Which design fits?
- A bank already uses a private interconnect into the cloud on-ramp, and the new requirement is to steer that traffic across the provider core. Which design meets the steering requirement?
- EVPN routes for a data-center interconnect are present, but the segment-routing transport that should carry them between the sites is down. Which fault is that?
- Inside one leaf-spine fabric, hosts on different racks lose Layer 2 reachability. The fabric extends those segments with EVPN and VXLAN, and a separate branch pseudowire is up. Where is the fault?
- A mobile operator must hand traffic to a second carrier whose routers sit in another cage of the same neutral building. Which connection belongs in that building?
- Two retail data centers extend EVPN across a segment-routed core, and the failure is on that core rather than inside either fabric. Which encapsulation is in the failing path?
- A factory runs a single ACI fabric. A contract already permits one pair of endpoint groups inside the first VRF. The devices that fail are in two different VRFs, and no route is shared between those VRFs. Underlay ports are up. Where is the fault?
- Two small sites are joined only by an Ethernet service. The provider provisions this Ethernet service using a pseudowire. This service uses a point-to-point pseudowire. Hosts on that emulation can no longer reach each other. Which fault matches the path?
- A freight exchange already has a private interconnect into the cloud across a provider core. The new need is to steer flows onto one low-delay core path. What meets that need?
- A payroll bureau already encrypts its cloud path with IPsec across the public internet, but a network policy prohibiting public-internet transit forbids that internet crossing. What meets the rule?
- A hospital already sends imaging traffic over a provider MPLS VPN. The new contract says the payload must be encrypted on that path, not merely separated by the provider. What should be added?
- A clinic already uses a dedicated private interconnect into the cloud and then finds the fiber has no cipher. Confidentiality on that path is the new requirement. What adds it?
- A studio in a carrier-neutral building already uses a cloud on-ramp. It now needs a private fiber handoff to a second carrier cage in the same meet-me room. Which connection meets that handoff?
- Players in one metro reach a distant cloud region by hairpinning across the country. A carrier-neutral building in that metro can host a closer cloud termination. What should the design add?
- Inside one factory ACI fabric, endpoints that policy should permit cannot reach each other. The path has no data-center interconnect overlay and no pseudowire. Where does the fault belong?
- Each data center extends local segments with VXLAN, and EVPN between the sites rides a segment-routed MPLS core. Local tunnel endpoints still ping inside one site, but routes to the other site vanish when a core path fails. Where is the fault?
- Airline crew apps in one city hairpin through a carrier-neutral building across the country, where their only cloud cross-connect sits. A cloud-edge facility is already in their city. Which attachment shortens the path?
- A regional fiber provider and a national carrier already lease cages in the same carrier-neutral building and need to hand off a wavelength there. Which connection meets that handoff?
- A grocery chain already enters the cloud on a private interconnect, and its backup crosses the public internet and must be encrypted. The provider core does not need a new steering policy. Which design encrypts the backup?
- A clinic can reach its cloud virtual router only across the public internet, and patient records on that path must be encrypted. The provider's segment-routed core serves other sites and has no port into this cloud. Which design meets the requirement?
- The only circuit between two warehouse data centers is one point-to-point Layer-2 emulation, and that emulation is down. No fabric overlay, segment-routed core, or policy fabric carries this circuit. Which repair matches the path?
- Cloud on-ramp traffic must follow a low-latency provider core path and fail onto a second engineered path. Encryption is already handled elsewhere. What steers those core paths?
- A trading archive must reach its cloud on a dedicated port that does not cross the internet. Core steering already works, and encryption of an internet path is not the request. Which attachment fits?
- A video provider's packets are already on the carrier core, and the carrier must steer them onto one chosen path. Encryption is not the requirement. Which design matches the steering need?
- Two rail yards are joined only by a pseudowire. Signaling for that pseudowire is up, small frames cross, and large frames are dropped. A separate EVPN service between other sites is healthy. What explains the large-frame drops?
- A sports broadcaster must encode video beside the venue interconnect so the path into the cloud stays short, instead of hauling raw video to a distant region first. Which facility matches that need?
- Inside one ACI fabric, two endpoint groups have learned each other's endpoints, but application traffic between them is dropped. No pseudowire and no segment-routed core are on this path. The EPGs are in a policy-enforcing VRF, and no contract allows the required flow between them. Which fault fits?
- Two retail data centers advertise MAC addresses with EVPN, the core under that EVPN is segment routing with MPLS, and forwarding fails because the core label stack is wrong while the EVPN routes still exist at the edges. Which path is at fault?
- A telescope archive has its private interconnect down for maintenance, and the only backup into the cloud is the public internet. The archive still requires encryption on that backup. What should be added?
- Ship telemetry hairpins through a distant cloud region before anyone can process it. A carrier-neutral shipyard already hosts interconnects. Which addition shortens that path without becoming the home region?
- In a carrier-neutral building, three access networks are already on the local internet exchange. A regional provider wants to exchange routes with those three and does not want transit or a cloud port. Which arrangement matches?
- A clinic sends records to a cloud firewall across the public Internet, and the records must be encrypted on that untrusted path. No dedicated cloud interconnect is in place. Which design adds the encryption?
- A stock exchange keeps a single point-to-point Layer 2 circuit between two ports. One attachment circuit is down, and the path contains no EVPN, no VXLAN, and no ACI fabric. Which fault matches the path?
- A power-grid control center runs an ACI fabric. A contract already permits the relay flow, the underlay is up, and the leaf has no forwarding entry for the relay controller. Where is the fault?
- A seed vault already reaches the cloud on a private interconnect that stays in service. An auditor requires the vault records to be encrypted on that same path. What should be added?
- Two cache operators lease cages in the same carrier-neutral building and must exchange fill traffic there. Neither side needs a new cloud region. Which connection completes the exchange?
- Two canyon weather stations extend one VLAN with EVPN and VXLAN. The underlay between the leaves still pings, and one leaf never learns remote MAC addresses for that VNI. Where should the operator look?