Service Assurance and Optimization (15%)
300-540 · 45 questions
- Operators already collect flow records and router logs for the core. They need an active measurement of delay for a single SR policy. Which addition matches that measurement?
- A cloud-edge router should push interface counters to the assurance platform continuously. The team does not want a management station to poll the router on a timer. Which collection method matches that requirement?
- One tenant virtual firewall is unreachable. The VIM API still creates other instances, the compute host is up, and storage volumes still attach. The firewall’s console confirms its forwarding process has stopped and the vNIC path was verified independently. Which fault matches the evidence?
- A retail chain's cloud-controller API answers inside its target time, yet one virtual firewall misses its session-setup target. What does the healthy API-time figure evidence?
- Backbone engineers want supported interface operational-state leaves, such as link state, pushed as those values change from cloud virtual routers, rather than collected by a periodic poll. Which mechanism matches that requirement?
- A utility needs an immediate notice when a router power supply fails. Flow records and a slow counter poll are already collected. The notice must be an event from the router, not a reading from inside a guest. Which method matches?
- A retail virtual firewall's process table is stuck and its local filesystem is full. Routers and the host do not export those guest-internal readings, and router interface counters look normal. Which collector can see the process and filesystem state?
- A virtual probe must forward a very high packet rate and must skip the software switch on the compute host. Which design matches that forwarding requirement?
- One tenant guest is down, while its compute host stays up, its storage stays reachable, and the infrastructure API still serves other tenants. What failed?
- One tenant guest is stopped. Other guests on the same compute host still answer, their storage volumes are healthy, and the VIM API accepts calls. Which fault matches that evidence?
- An assurance desk wants interface counters from the provider fabric pushed continuously instead of collected by a periodic poll. Which method matches that collection model?
- Operators need records of which addresses communicated, on which ports, and how much traffic passed, exported from the cloud-edge routers. Which telemetry supplies those records?
- A virtual inspection guest must raise its packet rate. Profiles show the guest kernel network stack is the bottleneck, and the host software switch is not saturated. What change fits?
- Operators want interface counters from cloud routers pushed continuously, rather than pulled on a timer. The cloud controller and the service catalog are not the target. What should they enable?
- In a mapping lab, every guest on one compute host is down. Guests on other hosts still run, storage volumes still attach, and the VIM API answers. Host health and hypervisor logs confirm the compute host stopped running its guests. What fault is this?
- A port authority must show whether its virtual firewall is meeting an agreed session-setup objective. Host CPU averages and completed order counts are already on display. Which figure is evidence of that objective?
- A broadcaster must measure delay and loss on a segment-routed path between two studios. Flow records and device logs are already collected. What matches this path measurement?
- Service orders for a touring orchestra stay unfulfilled. The virtual router CPU is idle, and the cloud controller API answers quickly. Which view should operations read?
- A virtual router must forward at a high packet rate, and the guest must receive frames on a virtual function of the physical NIC so the software switch is skipped. Which acceleration matches?
- One virtual probe is down. Other guests on the same compute host are healthy, the VIM API answers, and storage volumes attach normally. What failed?
- One tenant virtual firewall is stopped. The VIM API still creates other instances, the compute host is up, and storage volumes still attach. Which fault matches that evidence?
- At a hosted studio cloud, every guest on one hypervisor misses its forwarding deadline. Guests on the other hypervisors are fine, disk reads succeed, and the API still lists that hypervisor as up. The affected host has sustained CPU saturation and elevated guest CPU scheduling wait; storage latency, NIC queues and packet-path counters are normal. Which layer is at fault?
- A supported Cisco Nexus switch drops packets during short egress-queue bursts between counter polls. It supports hardware microburst detection with threshold-triggered event records, but that feature is disabled and no queue events are logged. Which method can capture the bursts the polls miss?
- A packet-core team wants interface counters pushed continuously from the routers instead of pulled on a slow interval. Which method matches that continuous push?
- A clinic virtual firewall stays in the ACTIVE state, its system disk still shows reads and writes, and other guests on the same host are healthy. The firewall's management port is closed and its process list no longer shows the firewall process. Which fault is this?
- New instances fail because their image volume cannot be read, while compute hosts answer, the VIM API is healthy, and a running guest stays up. Which fault is that?
- Flow records already show volume on a video network segment-routed core, but not whether one path missed its delay target. What measures that path?
- A virtual router at a packet fabric forwards in the kernel, and that kernel path stalls at the required packet rate while the software switch toward the guest does not. What should take over forwarding?
- Instance scheduling stalls and the research-cloud API times out, while the request never reaches a running guest. Which view explains the stall?
- The cloud controller API is slow to answer while a sample guest looks idle. Which view shows whether the controller is the problem?
- Creating a port in the cloud has become slow. A running virtual firewall stays idle, and its streamed counters stay quiet. Which assurance view should be read for this slowdown?
- A new virtual probe stays in an error state because its volume will not attach. Other guests on the same compute host keep running, and the infrastructure API still answers. The block-storage backend logs an explicit attach failure for the requested boot volume. Which fault domain is this?
- Transcoder instances on many different computes all stall on disk reads at the same moment, those computes still answer, and the cloud API can still list and start instances. Where is the fault?
- In a university research cloud, traffic still passes through virtual routers that are already running, and their volumes still read and write. Every new call to list flavors or create a port returns an error. Which layer has failed?
- After a peering cutover, one shared edge router is congested. Operations must learn which tenant conversations filled that router, not the delay of a core path. Which record should the router export?
- A packet-capture probe guest must take a very high frame rate, and the host software switch drops frames before they reach the guest. The probe is not the fabric forwarder. The NIC and hypervisor support SR-IOV, and the traffic to capture can be delivered directly to the probe’s VF. What removes that drop?
- A mobile packet gateway already receives frames on an SR-IOV virtual function, so the host software switch is not on the path. The guest still handles every packet through the kernel network stack and cannot keep the rate. The application stays. The gateway supports a DPDK packet-I/O mode, and its assigned VF has a compatible poll-mode driver. Which change addresses the remaining limit?
- A film studio's orchestration board shows every virtual-firewall order completed, while users still report failed inspection sessions on the firewall that is already running. What does the completed-order figure evidence?
- A syslog collector guest on an NFV host emits only a few messages each second and has no packet-rate target. Which data path matches that guest?
- Live broadband gateways keep forwarding, the compute hosts answer, and the VIM API answers, but every new volume attach fails with a storage-backend error. Which fault matches the evidence?
- A regional cloud controller answers slowly. Guest CPUs are idle, and the MANO view still shows the service as deployed. Which indicators explain the slow controller?
- Creating a port through the payments cloud API has become slow, while guest CPUs stay idle and the virtual firewall keeps forwarding. Which view shows that slowdown?
- Several packet-gateway guests on one ferry compute host drop together when that host loses power. Guests on other hosts stay up, volumes stay readable, and the cloud API still accepts calls. Which fault is this?
- A museum virtual firewall looks healthy on the management and orchestration view, and the cloud controller is fast. The open question is how many sessions that firewall drops. Which indicators should be read?
- A cement plant router rebooted overnight. Flow records and path delay look normal, and the operator needs the reboot text and the process restarts. Which record supplies them?