A clinic virtual firewall has two uplinks that both end on one provider edge and share that edge upstream. How should the attachment change so one provider failure does not isolate the firewall?
Select an answer to reveal the explanation.
Short Explanation
Two doors on the same hallway still share one exit to the street. You home the firewall to two independent providers so one provider failure cannot isolate it. Another link on the same edge, extra VLANs on that upstream, and a second address toward the same device all share one failure.
Full Explanation
Multihoming connects the site or device through multiple attachments. To survive the failure in this scenario, put the attachments in separate failure domains and verify that traffic can use either path. Two links, two VLANs, or two addresses that still leave through one provider edge share that edge and its upstream. The clinic firewall needs two independent providers, each with its own upstream, before a provider failure is survivable. Attach the firewall to two independent providers so each path has its own upstream failure is the design that meets this requirement. Add another link on the same provider edge beside the uplinks that already share that edge is the wrong fit because another link on the same edge still dies when that edge or its single upstream provider fails. Split the current attachment into two VLANs that still leave through the same upstream path is the wrong fit because two VLANs on one attachment are only logical splits of a path that still shares one upstream failure. Add a second address on the current interface pointed at the same provider edge device is the wrong fit because a second address toward the same device adds no second provider and no second failure domain. For a stateful firewall, verify session continuity separately from reachability. Exam caveat: Two provider edges count as multi-homing only when they do not share the same upstream failure, the same power, or the same single fiber leaving the building. Operational check: Confirm each firewall uplink terminates on a different provider or an independent device, and trace both paths until they reach separate upstreams.