One virtual probe is down. Other guests on the same compute host are healthy, the VIM API answers, and storage volumes attach normally. What failed?
Select an answer to reveal the explanation.
Short Explanation
One dark window does not mean the building lost power, locked its doors, or lost its files. You treat this as a guest fault because the other guests, the VIM API, and storage are still healthy. A compute fault, a VIM API fault, and a storage fault would show up on those other pieces.
Full Explanation
A single guest can fail while the compute host, the VIM API, and storage stay healthy. This virtual probe is down, other guests on the same host are up, the API answers, and volumes still attach. Start with the affected instance’s status, fault record, console, and its own attached volume. Other healthy instances and successful API calls rule out a broad outage but do not establish this instance’s cause. A compute fault would disturb the other guests. A VIM API fault would show failed API calls. A storage fault would show failed volume attachment. A tenant guest fault limited to the virtual probe that is down on an otherwise healthy host remains the best fit after those instance checks. A compute fault on the host that is still running the other guests without trouble is the wrong fit because it would disturb those other guests, and they are still healthy. A VIM API fault while the cloud API is still answering operator requests is the wrong fit because the API is still answering. A storage fault while volumes are still attaching for the guests that remain healthy in that other design is the wrong fit because volumes are still attaching. Exam caveat: Do not open a VIM or host incident from one failed guest. Operational check: Verify instance status, fault, console and its volume before assigning the fault to the guest.