High Availability (20%)
300-540 · 60 questions
- A tenant needs its own subnets and a controlled path out of the cloud, separate from other tenants and from the provider underlay. Which construct fits?
- A cloud fabric peers BGP with three provider edges that advertise one destination at equal preference. Traffic for that destination should use all three exits. The three BGP paths meet the platform’s multipath eligibility rules, and the forwarding platform supports at least three paths. Which forwarding design fits?
- Users of a clinic portal cannot connect after one load-balancer node stops responding. Name resolution still returns the site address, and the route to the site remains installed. Which resilience model matches the failure?
- The cloud fabric already speaks OSPF to two physical routers. Both links have equal cost, but traffic uses only one next hop. The operator wants both next hops used. Which change fits this fabric?
- Subscribers reach a virtual packet gateway through a load balancer. After one balancer node froze, traffic kept hashing to it and sessions stalled. DNS and the BGP next hops toward the site stayed healthy. Which change matches the failure?
- A tenant in a provider cloud needs its own subnets, its own route table, and a controlled path out to its VPNs. The tenant must not share one broadcast domain with other customers. Which construct is that?
- A clinic virtual firewall must stay reachable if one upstream provider fails completely. The two attachments must not share one upstream router. Which design fits?
- A customer router must dual-home to two provider edges as one logical Ethernet bundle so either edge can fail without creating a loop. Which design fits?
- A virtual broadband gateway keeps its control process in one VIM. The operator wants a standby for that process if the active process fails, on a different compute host, without moving the service to a second cloud. Which placement meets that requirement?
- A clinic virtual firewall has two uplinks that both end on one provider edge and share that edge upstream. How should the attachment change so one provider failure does not isolate the firewall?
- A rail cloud separates its VIM controller/API services from forwarding nodes. Existing flows require no controller exchange during the planned active-to-standby handoff, and forwarding nodes remain healthy. What does that controller failover cover?
- A regional hospital network connects its imaging archive to a service-provider cloud fabric over two equal-cost uplinks and must keep both next hops active for resilience. Both uplinks advertise the same destination through BGP, and their paths satisfy this router’s multipath eligibility rules. Which design keeps more than one next hop alive?
- Traffic from a cloud fabric toward the physical network should keep several equal-cost next hops in service at the same time. The physical routers advertise the destination through BGP, and their paths meet the platform’s multipath eligibility rules. Which design provides those next hops?
- A packet-core control process needs a hot standby in the same cloud so a control failure is covered without a second unrelated cloud. Which placement matches that control-plane requirement?
- Name lookups for a clinic cloud stop after its only recursive resolver fails, while existing routes and application health checks stay intact. Which resilience matches the component that failed?
- Harbor grain-terminal clients use only one resolver, and that resolver has stopped. Application routes are present and both load-balancer nodes pass health checks. What covers this failure?
- A botanical garden router is cabled to two provider edges. Both links forward and a loop has formed. The garden wants one Ethernet bundle so either edge can fail without a loop. What design fits?
- A ferry terminal connects to two provider edges in the same hut, and both edges reach the core through one shared fiber splice. A cut at that splice isolates the terminal. Why does this dual-homed design fail to survive the splice cut?
- A cloud fabric facing a mint runs IS-IS. Two paths have equal cost, yet the edge installs only one next hop. What should the edge install?
- A marina virtual broadband gateway holds two provider sessions, and both leave through one virtual NIC on one compute host. A host failure drops both sessions. What makes this attachment multi-homed?
- A conference provider runs one virtual session border controller on a single compute host. Maintenance of that host removes the service. Links on the host are already duplicated. What placement fixes the host fault?
- A virtual CGNAT function loses all forwarding when its only compute host fails. The control standby in the same VIM stays up and still has nothing to forward. What should be added?
- A credit-union firewall has two circuits that both fail when one upstream carrier has an outage. One provider failure must leave another provider in service. What attachment meets that goal?
- A credit union is moving teller applications into a public cloud and needs its own subnets, route tables, and a controlled path back to the branches. Which construct is that tenant network?
- A regional bank must keep its payment-verification VNF online if any single provider or access device fails. What design fits that requirement?
- A video platform already peers BGP from its cloud edge to three provider routers over equal-cost links and needs all three next hops used for forwarding. The three BGP paths meet the platform’s multipath eligibility rules, and the forwarding platform supports at least three paths. Which design installs more than one next hop?
- At a stadium, name lookups fail while the next hop still forwards and the application load balancer still passes health checks. A second resolver is idle. What should take the lookups?
- A virtual router in one cloud drops traffic when its compute host or its top-of-rack switch fails, even though its control process already has a standby. Which addition covers the data plane?
- A factory virtual firewall must keep working if one upstream provider fails. Both current links ride the same metro fiber into that one carrier. Which change is real multi-homing?
- Two application teams each have a virtual private cloud and need a controlled path between them without joining the provider underlay. Which design fits?
- Two equal-cost uplinks from a cloud fabric already sit in one OSPF area, and both next hops must stay in use. Which forwarding design fits?
- A university research lab needs its own isolated network inside a service-provider cloud, with private subnets for compute and storage plus a single controlled path to the Internet, separate from the provider transport. What provides that tenant space?
- A video portal still resolves in DNS and the load balancer marks both nodes healthy, yet sessions fail when the only route toward the fabric withdraws. Which resilience matches that failure?
- A virtual firewall has two uplinks that both terminate on the same provider edge router. Which change actually multi-homes it?
- Resolvers answer and the routes stay up, yet a ticket-seller load balancer keeps sending new sessions to a silent pool member while another member is healthy. What should change?
- A university research portal hosted in a service-provider cloud must keep resolving names when one DNS server fails. The sites already have two routing next hops, yet an outage of the single configured resolver still stops logins. Which design fits?
- A studio edge has two equal-cost paths installed toward the cloud. One large transfer fills only one path, the other path stays nearly idle, and smaller flows use both paths. What explains the one-sided transfer?
- A cloud edge learns two equal-cost OSPF paths toward the physical network and still forwards on only one next hop. How should both paths carry traffic?
- An airport firewall sends all traffic to one provider and uses a second provider only after the first withdraws its routes. The providers do not share an upstream failure. A reviewer says this is not multi-homing because traffic is not split. What is the right conclusion?
- A clinic buys two carrier circuits for a virtual router, but both enter through one building riser and both terminate on one upstream router. What attachment survives a failure of that shared router?
- A mobile-core cloud already runs an active controller and a standby controller in the same VIM. User traffic still stops when the single packet-gateway forwarding process crashes. What does the controller pair leave uncovered?
- A museum moved its portal to a new address. The resolver now answers with that new address, the route to it is installed, and the load balancer there is healthy. Some clients still open the retired address. What failure mode is this?
- A regional hospital runs its patient portal on backend servers in two data centers behind a service-provider load balancer. One server must be able to fail so new requests can be directed automatically to the surviving backend after failure detection, with the balancer detecting the failure automatically. What fits?
- A concert-venue firewall is dual-homed with EVPN link aggregation. The bundle is up and both provider edges are forwarding. The firewall receives two copies of each broadcast. What is missing?
- Clients resolve the service name, the load balancer answers, and its health checks pass. Return traffic from the balancer stops when one uplink fails, because that uplink is the only next hop. What resilience is missing?
- A virtual CGNAT control process already has a standby on another compute in the same cloud, yet packets died when the only top-of-rack in the data path failed. Which addition covers that failure?
- A power-utility cloud fabric learns two equal-cost OSPF paths toward campus and forwards on only one of them. BGP is not running on those adjacencies. Which change gives equal-cost multipath?
- Both uplinks of a ferry-terminal virtual firewall are pinned to the same leaf, so a reload of that leaf drops every session. A second carrier name would still land on that leaf. Which change is real multi-homing?
- A port-authority portal name resolves from both resolvers, and both load-balancer nodes pass health checks, but the only route to the service prefix has withdrawn. Which fix matches the failed component?
- A regional bank uses a provider-hosted virtual firewall with two instances for continuity, but both instances went down when one compute host failed. The two instances already have supported automatic firewall failover, the required state handling, and independent usable network paths. Which scheduler placement policy removes their shared compute-host failure?
- A Cisco IOS XR cloud edge uses ordinary equal-cost BGP multipath with a path limit greater than one and no unequal-cost or IGP-metric-ignore feature. All other multipath eligibility checks pass for two paths to one prefix, but one BGP next hop has a higher IGP metric. Only one path is installed. Why is the second path left out?
- A harbor crane cloud fabric runs IS-IS toward two physical routers at equal cost, yet forwarding uses only one next hop. Which change keeps both next hops alive?
- A hospital virtual firewall has two uplinks, and both of them terminate on the same provider edge router, so a reboot of that router isolates the firewall. Which change removes that shared failure?
- A warehouse firewall must dual-home to two provider edges so one edge can fail, and the two links must behave as one bundle without a forwarding loop. Which design matches that requirement?
- A winery tenant wants guest devices isolated from the production cellar network, with their own subnets and a controlled exit. Which design supplies that isolation?
- A retail checkout name resolves to the live site, and the load balancer at the live site is healthy. Traffic still arrives at a failed site because a more-specific route to the failed site is preferred over the aggregate that covers the live site. Which failure mode is this?
- Shoppers resolve the store name, and the route to the checkout site is up, but one load-balancer node is dead and still receives new sessions. Which fix matches the component that failed?
- A ski resort firewall has two fibers, and both fibers terminate on the same provider router in the village hut. One router failure still isolates the resort. Which change is real multi-homing?
- A rural clinic network must stay reachable if its primary upstream route fails, and adding name servers alone will not fix a lost route. Which design provides routing redundancy?
- A stadium ticket site resolves to the right address, the route is correct, and both load-balancer members pass health checks. Every spectator arrives from one shared address, and source affinity sends all of them to one member until that member overloads. What failure mode is this?