A port-authority portal name resolves from both resolvers, and both load-balancer nodes pass health checks, but the only route to the service prefix has withdrawn. Which fix matches the failed component?
Select an answer to reveal the explanation.
Short Explanation
A missing road is not fixed by printing another map when the map you have is already right. You add a second next hop for the service prefix, because the name resolves and both load-balancer nodes are healthy. Another resolver, another balancer node, and anycast DNS repair name lookup or the balancer tier.
Full Explanation
DNS, routing, and load balancers fail separately. Here resolution works and both balancer nodes are healthy, while the only next hop toward the prefix has withdrawn. A second next hop is the resilience that matches a routing failure. Another resolver or anycast DNS would matter if the name failed. Another balancer node would matter if a node failed its health check. A second next hop for the service prefix so traffic still forwards after one route withdraws is the design that meets this requirement. A third recursive resolver so name lookup has another server besides the two that already work is the wrong fit because another resolver protects name lookup, and both current resolvers already answer with the correct address. A third load-balancer node beside the two nodes that already pass their health checks is the wrong fit because another load-balancer node protects the balancer tier, and both existing nodes already pass health checks. Anycast for the portal name so DNS stays up even though name lookup is not what failed is the wrong fit because anycast DNS keeps the name reachable, and the name is already resolving while the route is gone. Exam caveat: Add a resolver or anycast DNS when clients cannot resolve the name, and add a balancer node when a health check is what fails. This outage is routing. Operational check: Withdraw one next hop in a test and confirm the prefix still forwards on the remaining hop while DNS and both balancer nodes stay healthy throughout.