One tenant guest is down, while its compute host stays up, its storage stays reachable, and the infrastructure API still serves other tenants. What failed?
Select an answer to reveal the explanation.
Short Explanation
One dark apartment in a building with the lobby lights on is that apartment's problem. You treat this as a tenant guest fault because the host, the storage, and the infrastructure API are still up. A compute-host fault, a storage fault, and an infrastructure API fault would reach further than one guest.
Full Explanation
A guest can fail while the compute host, the storage, and the virtualized infrastructure manager API stay healthy. Those three layers fail differently: a compute fault hits guests on that host, a storage fault hits the disks, and an API fault hits controller calls for many tenants. Start with the affected instance’s status, fault record, console, and its own attached volume. Other healthy instances and successful API calls rule out a broad outage but do not establish this instance’s cause. The tenant guest, whose failure leaves the host, the storage, and the infrastructure API up fits this isolated scope. The compute host, a fault that would disrupt the other guests scheduled on that same host is the wrong fit because a compute fault takes down guests on that host, and this host stayed up. The storage path, a fault that would make disks unreachable for guests that use that storage is the wrong fit because a storage fault makes disks unreachable, and this path is still reachable. The VIM API, a control fault that would break instance calls for many tenants at once is the wrong fit because a VIM API fault breaks calls for many tenants, and this API still serves calls. Exam caveat: Check the blast radius before you blame the controller API. Operational check: Confirm only this guest is down while host, storage and API succeed elsewhere, then inspect that instance.