Secure Network Infrastructure (25%)
810-115 · 75 questions
- On a mining-site conveyor cell, several copper ports on a Cisco Industrial Ethernet switch have no devices cabled, yet they remain administratively up. Which baseline change should come first?
- Technicians telnet to a Cisco Industrial Ethernet switch on a building-automation network, and that management address sits on VLAN 1 with the controllers. Which baseline corrects this?
- A reactor-cell PLC is the only device that should ever use port Gi1/3 on a Cisco Industrial Ethernet switch. Which port-security choice matches that baseline?
- A factory must keep the robot-cell VLAN off the enterprise ERP VLAN, while still letting one historian query the cell. Which design matches that goal on Cisco Industrial Ethernet switches?
- A hydro plant must send historian readings to the enterprise data lake, and no packet from the enterprise may reach the plant network. Which device enforces that property?
- A pharmaceutical packaging cell's Cisco IE switch still answers on the web interface and on Telnet. SSH is already working for the engineers. Which hardening step fits the baseline?
- A grain elevator proposes moving an emergency-stop trip between two safety controllers off a dedicated wire and onto the office wireless LAN. Which implication should stop that design?
- A technician applied an extended ACL on a packaging-cell switched virtual interface to stop a panel PC from reaching a PLC. Both are in that same VLAN, and the PC still connects. Why?
- A blower PLC must stay online if someone plugs a second device into its Cisco IE access port. The port should drop the extra MAC, record the event, and keep forwarding the PLC. Which violation mode matches?
- A container-port Cisco Industrial Ethernet switch still answers SNMP polls sent to the community string public. Which change belongs in the hardening baseline?
- Any host on a cement-plant network can open SSH to the kiln-cell Cisco IE switches, including hosts on the controller VLAN. Which control narrows that management access?
- On a sawmill Cisco IE switch, every technician logs in with one privilege 15 account. Operators only need to view status, and engineers change configuration. Which credential baseline fits?
- A factory MES must query one cell historian and receive the answer back. No other enterprise host may reach the cell. A data diode currently exports copies one way. Which design fits this query?
- Cement-plant technicians want tablets on wireless for rounds. Someone suggests bridging that SSID straight into the controller VLAN and printing the shared key on the cabinet. Which design is sound?
- A pharma packager enabled sticky port security on a blister-line PLC port, saw the PLC MAC go secure, then reloaded the Cisco IE switch without saving. The secure MAC was gone afterward. Which explanation fits?
- On a fertilizer plant, the trunk between two Cisco IE cell switches uses the PLC control VLAN as its untagged native VLAN. Which change matches a secure segmentation baseline?
- An oil-platform Cisco router still honors IP packets that select their own forwarding path across the platform. Which hardening step matches the baseline?
- At an auto-body plant, an unknown wireless access point is plugged into a Cisco IE access port on the weld-cell VLAN. Which issue should the crew treat that as?
- A wastewater plant's network monitor still polls cell switches with the SNMP community string public, and that string is printed on a shared diagram. Which management change fits?
- A bottling-line panel hides an unmanaged switch that connects a PLC, an HMI, and a drive to one Cisco Industrial Ethernet access port. A technician wants port security on that port with a maximum of one MAC address. Which outcome should stop that plan?
- A mill mirrors cell traffic to a monitoring laptop with a SPAN session and then treats that copy as the barrier that stops enterprise commands from reaching the PLCs. Which statement is accurate?
- A building-automation Cisco Industrial Ethernet switch still accepts SSH version 1 to its management address. Engineers already use SSH version 2 clients. Which change fits?
- A rail yard puts each interlocking in its own VLAN, then routes the VLANs on a Layer 3 switch with no policy between levels or toward the enterprise. Which design closes that gap?
- A baseline review of a Cisco Industrial Ethernet switch at a water intake shows IP source routing is still enabled. Which hardening change fits?
- A designer wants a firewall between a filling-line PLC and its remote input-output rack so every cyclic exchange is inspected. Which placement decision fits?
- A crane PLC port on a Cisco Industrial Ethernet switch err-disabled after a laptop shared the jack. Recovery for psecure-violation is on, and the laptop is still plugged in. What does the port do when the timer expires?
- An engineer at a cement kiln bridges a laptop between a phone hotspot and a live PLC switch so a remote colleague can watch the kiln screen. Which risk does that create?
- A wastewater Cisco Industrial Ethernet switch still runs a DHCP pool on the lift-station VLAN. Every PLC uses a static address, and a laptop plugged into the cell receives an address from that pool. Which baseline change fits?
- A Cisco IE switch in a kiln area still protects privileged mode with a type 7 password. Which change matches Cisco password guidance?
- A food plant's boundary rule was supposed to let only the historian query the batch-cell PLCs. The live ACL permits the entire enterprise subnet instead. Which change matches that design?
- A bottling-line designer wants a stateful firewall between the filler PLC and its variable-speed drives so every cyclic frame can be inspected. Which placement should be chosen?
- Someone asks to set port security with a maximum of one MAC on the trunk uplink between two cell switches at a bakery. Which response is sound?
- A contractor plugged a small access point into a live access port inside a bakery oven cabinet so phones could join the network. That port is in the oven-cell VLAN. Which risk is this?
- A sawmill has a firewall between the control zone and the enterprise zone. A tech also finds a patch cable that ties the two switches together around that firewall. Which action fits?
- SSH sessions to a Cisco IE switch in a remote pumphouse stay open for days after the engineer walks away. Which change fits?
- Port security will be enabled on a filler PLC port before the PLC is reconnected. A laptop is currently plugged in. Which configuration avoids learning the laptop as the allowed address?
- A factory created a VLAN for each production cell, then removed the firewall between the cells and the enterprise, arguing the VLANs are enough. Routes from the enterprise still lead toward the cell switches. Which design corrects that?
- A Cisco IE switch in a paint cell is still offering BOOTP addresses on the PLC VLAN. Controllers are supposed to use fixed addresses. Which hardening step fits?
- A contractor plugs a consumer access point into a live cabinet port on a container-terminal crane cell so a tablet can join. Which risk does that create?
- A pipeline pump-station trunk uses VLAN 20 for PLC traffic and also uses VLAN 20 as the native VLAN. Which baseline change is sound?
- Operators can SSH to a port-crane Cisco Industrial Ethernet switch from any VLAN, including the crane PLC subnet. Which change matches a secure management baseline?
- A food-plant bagging port err-disabled after a port-security violation. Recovery for that violation is enabled, and the unknown laptop is still plugged in. What should you expect when the timer expires?
- A power-plant historian export crosses a data diode. A power fault hits the diode, and an engineer fears it will become a two-way cable. Which failure behavior should the design require?
- An electrician finds a small wireless router plugged into a live switch port inside a cold-storage cabinet. Contractors have been joining its SSID. Which problem is this?
- A passenger-station switch displays a legal warning banner on Telnet, and the crew treats that banner as the management security control. Which statement is sound?
- A site exports historian data through a data diode and now wants to push a PLC firmware file back through that same diode. Which approach fits the diode's limits?
- A building-automation Cisco switch still answers SNMP using the community string public. Which baseline change addresses that exposure?
- A factory trunk links a robot-cell switch to the aggregation switch, and only the cell supervisory VLAN must cross it. Which design matches that goal?
- When the authentication server is unreachable, every technician at a sawmill falls through to one shared privilege 15 account on the Cisco Industrial Ethernet switch. Which fallback fits?
- A panel uses a small unmanaged switch so one PLC and one local HMI share a single Cisco IE port. Port security allows one MAC, and the port is err-disabled. Why?
- A technician finds an unknown wireless access point patched into a live switch port inside a bottling-cell cabinet. Which risk does that access point create?
- A trunk into an office building on a mining site allows every VLAN, including the conveyor safety VLAN. Which change fits the segmentation design?
- Every contractor tablet at a cement plant joins the maintenance wireless LAN with one pre-shared key that is posted in the workshop. Which change improves that access?
- A one-MAC port-security setting on a Cisco Industrial Ethernet switch err-disables when a technician puts an unmanaged desktop switch under a panel and hangs the PLC plus a laptop from it. Which fix fits?
- At a gas compressor station, any address can SSH to a Cisco Industrial Ethernet switch, and the switch still accepts SSH version 1. Which management change fits the baseline?
- The historian diode at a hydro plant fails during a storm. Operators worry the failure opened a path from the enterprise back into the plant. Which outcome fits a data diode?
- A rail crew adds only a legal warning banner to a Cisco Industrial Ethernet switch and changes nothing else. What security effect does that banner have?
- An oil-terminal crew manages Cisco Industrial Ethernet switches only from addresses on the loading-rack VLAN. A storm on that VLAN also takes away switch management. Which design avoids that coupling?
- A canning line needs a hard stop for sessions that are not allowed to cross from the enterprise, and a separate copy of that traffic for monitoring. Which design fits?
- A cell switch uses port-security violation protect on a PLC port. A laptop was connected overnight and nobody received a log. The PLC still forwards. Which explanation fits?
- On a Cisco IE switch in a building-automation closet, packets should not be allowed to choose their own forwarding path. Which hardening step matches that goal?
- A refinery ACL on the routed path to a distillation PLC permits only the local HMI Modbus session. A contractor laptop on another subnet cannot connect, and no ACL line names that laptop. Why did the laptop fail?
- At a wastewater plant, a technician bridges a phone hotspot to a cabinet switch so a vendor laptop can reach a blower PLC without the plant remote-access path. Which problem is that?
- A paper-mill utilities switch, a Cisco Industrial Ethernet switch, still accepts SNMP reads that use the community string public. Which baseline change should come first?
- Logs on a Cisco IE switch show a long run of failed SSH logins from a single address against the VTY. Which control slows that guessing?
- An engineer enabled port security on a Cisco IE port that is still in dynamic auto mode, and the feature will not do its job for a single PLC. Which correction fits?
- A beverage plant put each cell on its own VLAN, then routed those VLANs into the enterprise on a Layer 3 switch with no firewall. Which gap remains?
- A review of a Cisco IE switch in a grain cell finds the finger service still willing to answer queries. Nothing in the cell uses it. Which hardening step fits?
- On a mining-conveyor trunk, the native VLAN is the same VLAN as the conveyor PLCs. Which risk does that choice create?
- On a Cisco IE trunk between two water-plant cell switches, the PLC VLAN is configured as the native VLAN. Which baseline change fits?
- A trunk from an oil-terminal cell switch toward the enterprise core permits every VLAN, including the PLC VLAN. Which change fits?
- A power plant wants its Level 3 historian to query turbine PLCs through a new static route on the cell switch, with no firewall on that path. Which design fits instead?
- An engineer applied an outbound ACL on the management SVI of a Cisco IE switch and still sees SSH sessions arrive from hosts that ACL would deny. Which explanation fits?
- A failed mixer PLC was replaced overnight. Port security still has the old PLC's MAC as the only secure address, and the new PLC cannot forward. Which fix fits?
- Cell A and cell B are in different VLANs. Both switched virtual interfaces are up and routing, and no access list is applied. A laptop in cell A opens a session to a PLC in cell B. Which statement fits?