Visibility and Risk Assessment (30%)
810-115 · 90 questions
- A paper-mill crew says the new OT visibility tool is only a second asset list. The security lead wants its communication baseline. What does that baseline add that a static inventory does not?
- On a beverage packaging line, the OT visibility tool reports a laptop MAC that was absent from yesterday's baseline and is now speaking to a PLC. The change owner confirms that this laptop was not authorized to connect. Which issue is that?
- Cisco Cyber Vision reports a new activity on a steel-mill cooling PLC: a maintenance laptop that only read registers last week has now written Modbus holding registers. No change ticket exists. Which reading fits?
- A visibility tool flags a critical vulnerability on a paint-shop PLC that is running production. The vendor patch needs a reboot and has not been tested on this line. Which remediation fits?
- Two boilers show the same firmware vulnerability. Boiler A is a safety controller with a routed path from the enterprise historian VLAN. Boiler B is an identical spare on a bench with no uplink. Which risk reading is sound?
- A water-treatment plant needs an inventory of the filtration-cell PLCs and HMIs without interrupting the process. Which visibility approach fits that constraint?
- At an automotive stamping plant, the visibility baseline shows the engineering workstation talking to controllers only on day shift. Tonight it opens the same sessions at 02:00 with no ticket. Which issue is that?
- Inside a bakery proofer's Level 1 VLAN, the visibility tool shows SMB file-sharing sessions from a panel PC to a new address, next to the usual cyclic controller traffic. Which issue is that?
- A mine concentrator placed its only OT visibility sensor on the enterprise firewall. Cell controllers talk to each other all day and never appear. Which placement fixes that gap?
- Cisco Cyber Vision shows the firmware version on a cement-kiln PLC no longer matches yesterday, and no change ticket exists. Which reading of that event is appropriate?
- A brewery engineering workstation has a critical operating-system vulnerability. It is not a controller, and production does not need it until tomorrow's change window. Which remediation fits?
- A terminal's visibility profile shows an unreachable Level 1 PLC that speaks an unauthenticated protocol, and a vendor jump host with a critical remote flaw and active vendor logins. Which risk reading is sound?
- A tire plant's visibility tool shows remote-desktop sessions from an IT subnet into the Level 2 HMI VLAN. The baseline for that VLAN is HMI-to-controller traffic only. Which issue is that?
- On a water-distribution cell with no redundant controller pair, the visibility tool shows two MAC addresses answering for one pump-PLC IP and the HMI session keeps dropping. Which issue is that?
- Cisco Cyber Vision associates a known vulnerability with one oil-pipeline pump PLC that the engineering workstation can reach. No exploit traffic has been observed. Which reading of that event fits?
- Cisco Cyber Vision reports a new component on a juice-plant filler VLAN. The vendor string is a small office switch the plant does not use, and no ticket exists. Which reading fits?
- A distribution relay has a known vulnerability and the vendor has no patch in this year's outage plan. The feeder must stay in service. Which remediation fits?
- A wastewater utility's configuration database lists domain-joined servers and contains no clarifier PLCs. Which visibility gap explains that result?
- On a tire-curing cell, the visibility tool shows the same controller-to-drive cyclic exchange recorded on recent shifts, with the same peers and the same protocol. Which judgment fits?
- Cisco Cyber Vision matches a known vulnerability to the firmware it observed on one granulation-skid drive at a pharma plant and shows no exploit traffic. Which reading fits?
- A sawmill safety PLC that guards the head saw has a firmware flaw. The vendor procedure needs a tested outage and a signed image. A forum file is proposed for tonight while the line is cutting. Which remediation fits?
- Two winery findings are both marked critical. One is classic Modbus on a mobile skid with no uplink. The other is a domain-joined bottling HMI that enterprise hosts can reach. Which risk order is sound?
- Two network-connected Windows PCs at an oil terminal share one vulnerability identifier. One is the safety engineering station for the loading-arm shutdown, and the other is a lobby weather display. Assume both PCs have comparable exploitability and exposure to the vulnerability. Which risk reading is sound?
- A mine-hoist security monitor collects Windows event logs from HMIs and servers and has never shown a message between the hoist PLC and its drive. Which visibility gap is that?
- The same firmware flaw shows up on two machines at a bottling plant. One is the engineering station that can reach every cell. The other is a bench laptop that is powered off in a cabinet. Which asset should be worked first?
- On a mining-hoist cell, the visibility tool shows one new host opening connections to PLC addresses in numeric order while the usual drive cycles continue. Which issue is that?
- Cisco Cyber Vision reports a new activity at a dairy: an engineering station transferred a controller project into a running separator PLC, and no change ticket exists. Which reading fits?
- At a fuel terminal, a contractor wants to plug a laptop that was on public wireless that morning straight into the loading-rack switch to copy a trend file. Which remediation fits?
- A mine-hoist safety controller has a vendor bulletin, and maintenance wants to load a basic-process PLC image from a forum during the shift, with no proof test. Which remediation fits?
- A port's IT configuration database lists servers and laptops and shows no PLCs for the crane cell. Those PLCs do not run an endpoint agent and do not join the corporate domain. Which visibility gap is this?
- A warehouse spreadsheet lists every PLC by serial number and nothing else. A firewall change is waiting on that list. Which addition makes the inventory useful for the change?
- One maintenance window can take a vendor firmware update on a single drive. Two drives share the flaw. Drive A is on the safety network of a running press. Drive B is the same model on a bench with no network. Which choice fits?
- A grain-elevator PLC's baseline contains only its local HMI. Tonight that PLC opens a session to an internet address while the HMI conversation continues at its normal rate. Which issue is that?
- A visibility tool marks a critical flaw on a boiler-controller spare that is unplugged in a storeroom, and a medium flaw on the in-service boiler controller the enterprise can route to. Which ranking fits?
- Cisco Cyber Vision reports a new activity on a frozen-food spiral freezer: a laptop opened a programming session and downloaded logic to the PLC. No change ticket exists. Which reading fits?
- A brewery will add a deny-by-default firewall rule between the cellar and the site historian, but nobody has a current map of which hosts actually talk. Which step should come first?
- A mining concentrator deployed a collector that ingests only Windows event logs. It lists the HMI PCs and never names the flotation PLCs or the protocols among them. Which gap does that leave?
- During production in an automotive weld cell, visibility shows one laptop opening short connections toward every PLC address in the VLAN. Cyclic controller traffic is unchanged. Which issue is that?
- At a water-treatment plant, the visibility tool reports two devices answering for the same filter-PLC IP address, and the HMI session flaps. The cyclic traffic rate is unchanged. Which issue is that?
- Cisco Cyber Vision ties a vulnerability to one weld-cell robot controller that is in production and reachable from the cell HMI. It does not report a new device or a firmware-string change. Which reading fits?
- A rail traction substation has a vendor advisory on a protection IED. No vendor procedure exists for this hardware revision, and an engineer offers a firmware file from a public forum. Which response fits?
- An oil terminal has the same vendor advisory on two assets. The loading-arm HMI is domain-joined on the operations VLAN. The tank-gauge controller speaks only serial and has no IP address. The serial controller has no remote-access gateway or other path from the operations network, and physical access is controlled. Assume comparable vulnerability exploitability and operational impact. Which risk reading is sound?
- A pharmaceutical packaging-cell inventory records only an IP address for each controller. Which added facts make that inventory useful for OT risk decisions?
- An aeration-blower PLC at a wastewater plant has a known flaw and no patch that keeps the validated application. The blowers are in service. The lead says to virtual-patch the PLC. What does that mean here?
- Cisco Cyber Vision associates a known vulnerability with one assembly-cell drive because the drive firmware matches the affected build. No attack traffic is shown. Which reading fits?
- Cisco Cyber Vision ties a known vulnerability to one feeder-management PLC, including that PLC's firmware and the HMI that talks to it. No property change is shown. Which reading fits?
- A wastewater visibility feed shows the same HMI polling the same lift-station PLC at the usual interval with the same function codes as last week. Which reading fits?
- A refinery has the same firmware flaw on two controllers that are equally reachable from the operations VLAN. One is the burner-management safety controller. The other runs only yard lighting. Which risk reading is sound?
- A platform safety PLC has a firmware flaw. The vendor allows the fix only during a validated outage. A forum file is offered for install tonight while production continues. Which action fits?
- One firmware flaw is on a contractor tablet that joins the plant wireless network. The same flaw is on a spare panel PC that is powered off in a locked cage. Which asset is the higher immediate risk?
- A dairy pasteurizer PLC normally talks only to its local HMI. Visibility now shows sessions with an address on the enterprise subnet, and no change ticket exists. Which issue is that?
- After a ticketed wayside-PLC replacement, the rail visibility baseline still describes the removed controller. Which next step is right?
- Cisco Cyber Vision reports a new activity on a brewery fermenter PLC: an engineering station performed a program upload and took a copy of the controller logic. No change ticket exists. Which reading fits?
- A wastewater plant has two findings with the same critical label. One is unauthenticated Modbus on a skid with no uplink. The other is a domain-joined HMI that operators browse and that can reach many pump PLCs. Which risk reading is sound?
- On a pharmaceutical packaging line, a drive that normally speaks only to its PLC opens a session toward an enterprise subnet. The cyclic PLC traffic is unchanged. Which issue is that?
- Cisco Cyber Vision lists a vulnerability on a cement-kiln feed drive together with that drive's vendor, firmware, and cell. Which reading fits?
- A gas-plant safety PLC has a vendor bulletin that calls for a validated procedure and a proof test. The IT calendar wants a generic push tonight. Which remediation fits?
- A mining technician returns from travel and plugs a laptop that has been on public networks into the conveyor PLC switch. Which remediation fits before any logic work?
- Two online PLCs share a similar firmware weakness and both are reachable from the same engineering VLAN. One can trip a refinery reactor. The other only counts bottles. Which risk reading is sound?
- A printing plant inventories assets from Windows event logs only. The inventory collector ingests only Windows security logon events from domain computers; it has no industrial application logs or packet feed. The press PLCs never join the domain. Which visibility gap does that create?
- A water-plant PLC cannot take a vendor patch until next year's outage. The conduit currently allows any Modbus function from several hosts. The HMI only needs to read. Which change fits until that outage?
- A chemical plant's only visibility sensor watches the basic-control uplink. The safety controllers sit on their own network and never appear. Which gap is that?
- A packaging PLC's baseline is cyclic controller traffic only. The visibility tool now also shows that PLC sending cleartext HTTP to a new host. Which issue is that?
- Cisco Cyber Vision shows an activity on a kiln PLC that matches the HMI poll already in the baseline, at the usual rate, from the usual HMI. No other change is listed. Which reading fits?
- Two reachable controllers show the same vulnerability finding. One is a safety controller on a running press. The other is a lighting controller in the office wing. Which risk reading is sound?
- A mill adds an approved drive and the visibility tool alerts on every conversation that drive starts. The conversations match the change ticket. Which step fits?
- A daytime walkdown missed a clean-in-place skid that runs only after midnight. The team wants that skid in the OT inventory without scanning the cell during production. Which approach fits?
- The same class of flaw is found on two systems. One is the broker in the industrial DMZ that every cell uses to reach the enterprise. The other is a skid with no uplink. Which one is the higher immediate risk?
- A filler PLC still talks only to its usual HMI and drives, but the visibility tool shows that PLC's traffic volume far above the saved baseline. Which issue is that?
- Cisco Cyber Vision shows a new I/O module on a hoist PLC that was not in yesterday's component record. No change ticket exists. Which reading fits?
- A visibility tool shows two packaging PLCs exchanging writes after midnight. Their baseline has never included a conversation with each other. Which reading fits?
- A pharma batch reactor has a firmware bulletin for its safety controller. The vendor procedure requires a planned validation run, and the basic-control PLC is a different device. Which remediation fits?
- An oil-well pump drive has a known weakness, and the OEM image cannot be loaded until a scheduled outage. A colleague says to virtual-patch it by installing firmware now. Which compensating approach fits?
- A pharmaceutical packaging site sends only Windows event logs from its HMIs into the security monitor. Which gap does that leave in the cell?
- On a bottling line, the visibility tool reports two devices answering for the same PLC address during the same minute. Which issue is that?
- Cisco Cyber Vision reports a new activity in a factory robot cell: an unknown laptop sent a PROFINET DCP Set that changed a drive's device name. No ticket exists. Which reading fits?
- Cisco Cyber Vision reports a known vulnerability on one servo drive in a newspaper press, matched to that drive's vendor and firmware. No other component is listed. Which reading fits?
- Two controllers share one vulnerability record and both are reachable from the site operations VLAN. One is the safety interlock for a pharma clean room. The other runs lobby lighting. Which risk reading fits?
- A medium finding sits on the safety controller that the basic-control network can still reach. A finding with a harsher label sits on a lab PLC that has no process role and no uplink. Which asset should be ranked higher?
- An OT inventory lists IP addresses, vendors, and firmware, but not whether a controller is a safety system or basic control. A new finding is about to be prioritized. Which gap matters?
- During a normal production hour on a paint line, one host sweeps TCP ports across the cell while the PLC-to-drive cycle looks unchanged. Which issue deserves investigation?
- Cisco Cyber Vision reports a new activity on a container-port crane PLC: The local engineering station completed a program download to the crane PLC, and comparison with the approved project confirms that different controller logic was loaded. No change ticket exists. Which reading fits?
- A forum post offers a fixed firmware image for a wastewater safety controller with a known flaw. The vendor procedure has not been run. Which remediation is sound?
- A mining site shows two findings with the same critical label. One is a serial-only conveyor controller with no IP path. The other is a domain-joined HMI on the operations network. Which risk reading is sound?
- A team has NetFlow from the enterprise firewall and wants it to reveal which Modbus function codes the filler PLCs are using. The firewall does not sit inside the cell. Which approach fits?
- During a live dairy packaging batch, someone plugged an unapproved contractor laptop into the cell switch. Which first response fits?
- Cisco Cyber Vision associates a known vulnerability with the firmware of one paint-shop drive. No attack traffic is shown. Which reading fits?
- A bulletin covers a wastewater chlorine-feed safety PLC. The only image on the file share was built for the basic-process controllers, and the safety vendor's procedure has not arrived. Which remediation fits?
- Two engineering stations share the same malware exposure and both sit on the operations VLAN. One can change a gas-plant safety PLC. The other only edits lobby graphics. Which risk reading is sound?
- Two water-district pump PLCs share the same unauthenticated-protocol weakness. Pump A accepts sessions only from its local HMI. Pump B also accepts sessions from the enterprise reporting VLAN. Which risk reading is sound?