Cisco Cyber Vision reports a new activity at a dairy: an engineering station transferred a controller project into a running separator PLC, and no change ticket exists. Which reading fits?
Select an answer to reveal the explanation.
Short Explanation
Yesterday the separator ran the project operations had approved, and today a station poured in a new project with no ticket. You read that activity as a logic download, an unplanned change to the controller. A tag poll, a protection message between relays, and a DHCP lease do not transfer a project.
Full Explanation
Cisco Cyber Vision reports activities from the industrial traffic it decodes. A transfer of a controller project from an engineering station into a running separator PLC is a logic download. With no change ticket, the fitting reading is that a download occurred and that it stands as an unplanned control change until the dairy team explains it. The industrial action comes first. Authorization is the next question, not a reason to rename the action. GOOSE is a Layer 2 protection multicast used between substation relays. It does not refresh a separator PLC project in a dairy, and a retransmission of trips is not a project transfer. A historian tag poll reads values. It does not load a controller project, so calling the activity a routine analog read contradicts the action the sensor reported. A DHCP lease renewal assigns an address. It is not stored as a PLC project and it does not change the logic the separator is running. Exam caveat: the download might be legitimate work that skipped the ticket. You still start from the project transfer and then match it to a person and a request, rather than relabeling it as a read. Operational check: identify the engineering station and the separator PLC in the activity, compare the PLC project to the last approved copy, and open an incident if nobody requested the download.