5 Patient Safety
CPHQ · 43 questions
- During a busy trauma resuscitation in an emergency department, a physician calls out a verbal medication order across the room, and two nurses later realize the dose was misheard in the noise. Which communication practice from TeamSTEPPS best prevents this type of verbal order error?
- An adult intensive care unit experienced a near miss when a nurse almost connected an enteral feeding tube to a central venous catheter port because both lines used compatible luer connectors. Which human factors solution provides the strongest long-term barrier against recurrence?
- Following a wrong-site outpatient procedure, a hospital convenes a root cause analysis team. During the first meeting, a department chair asks which clinician should receive formal discipline so the review can close quickly. How should the quality facilitator guide the team?
- A hospital's patient safety officer reviews pharmacy technology logs and discovers that nurses on a medical-surgical unit override barcode medication administration (BCMA) alerts on 35% of morning doses by scanning spare patient wristbands taped to medication carts. What should the safety officer do first to address this workaround?
- A hospitalized patient suffers a severe allergic reaction after receiving a documented contraindicated antibiotic during a shift change. Following immediate clinical stabilization, what is the most appropriate response by leadership and the patient safety team?
- During an understaffed night shift, a nurse administers the wrong medication dose after pulling one of two look-alike vials stored side by side in an automated dispensing cabinet. How should leadership respond first under a Just Culture framework?
- Intensive care nurses silence dozens of pulse oximetry and telemetry alarms each hour because most alerts reflect brief motion artifacts rather than true clinical deterioration, causing staff to miss an actual arrhythmia alarm. Which patient safety intervention best addresses this hazard?
- A multi-unit hospital wants to catch emerging staffing, equipment, and clinical safety risks each morning before they lead to patient harm, rather than waiting for monthly incident summaries. Which patient safety practice best supports real-time hazard detection and escalation?
- A health system plans to replace all inpatient smart infusion pumps across its facilities and wants to prevent user-interface confusion and programming errors before signing a vendor contract. Which proactive human factors step should the safety team recommend?
- A pediatric oncology clinic plans to launch a new high-alert intravenous chemotherapy infusion workflow and wants to identify potential failure points before treating any patients. Which safety tool should the quality team use first?
- A community hospital's voluntary safety reporting system shows that near-miss submissions dropped by half over two quarters after a department supervisor publicly criticized a nurse for submitting a medication delay report. Which action should the patient safety officer recommend first to restore reporting?
- Following an unexpected patient death linked to a complex infusion pump programming error, the involved intensive care nurse experiences severe emotional distress, insomnia, and fear of returning to bedside duty. Alongside conducting a systems-based root cause analysis, what should the patient safety leader ensure is offered?
- A hospital's safety committee discovers that prescribers override 91% of computerized provider order entry (CPOE) medication alerts because low-value duplicate-therapy pop-ups appear on nearly every order. Which intervention best addresses this alert fatigue?
- After a wrong-dose insulin event in an acute care unit, a root cause analysis team proposes adding a mandatory second-nurse double-check and sending an email reminder to staff. Why should the patient safety officer push for a stronger action?
- A hospital relies solely on its voluntary incident reporting system to monitor inpatient medication harm, yet monthly adverse drug event rates remain near zero despite frequent pharmacy interventions on the wards. How should the patient safety officer uncover missed harm?
- A community hospital administers the AHRQ Surveys on Patient Safety Culture and receives an overall positive score of 74% across the organization, leading senior leaders to conclude no action is needed. However, the patient safety officer notices wide variation across departments. What should the safety officer do next?
- During an unexpected hospital-wide electronic health record downtime, senior administrators debate whether to pause surgical cases, while charge nurses and pharmacy technicians already know which manual order workflows are failing on the units. Which High Reliability Organization (HRO) principle should guide leadership?
- After a near miss in an outpatient dialysis clinic, leadership accepts a one-line conclusion that staff simply forgot to check machine settings without reviewing staffing ratios, alarm audibility, or scheduling pressure. Which High Reliability Organization principle is the clinic failing to apply?
- Over two weeks, pharmacy technicians catch three separate near misses where look-alike concentrated electrolyte vials were placed in the wrong automated dispensing bin, though no patient received a wrong dose. A unit manager suggests closing the log without review because no harm occurred. Which High Reliability Organization principle should the safety officer invoke to insist on a system review?
- A pediatric hospital finishes constructing a new acute stabilization bay and plans to begin admitting critically ill patients next week. Before opening the space, how should the patient safety team proactively identify hidden equipment, layout, and communication hazards?
- A primary care network discovers that several patients experienced delayed cancer diagnoses because abnormal chest imaging reports noting incidental pulmonary nodules were filed in the electronic health record without documented clinician acknowledgment or follow-up scheduling. Which safety safeguard best prevents this failure?
- While investigating a wrong-dose chemotherapy administration, a patient safety specialist notes both the nurse's miscalculation at the pump and longstanding gaps in pharmacy verification staffing, lighting, and order-entry design. How should the specialist classify those longstanding organizational gaps?
- A medical-surgical nurse notices a postoperative patient's blood pressure dropping and heart rate rising over two hours and needs to escalate the change immediately to an on-call physician. Which communication practice best supports a clear, actionable response?
- During morning rounds on a busy telemetry unit, a charge nurse notices two new float nurses bypassing bedside monitor checks because extra beds were placed in the hallway overnight. Which patient safety approach reflects a High Reliability Organization?
- A multi-hospital health system wants to compare near-miss medication and fall trends across six facilities, but each hospital currently uses custom free-text categories in its incident reporting software. What should the patient safety director establish first to enable system-wide learning?
- During a surgical procedure, a scrub technician notices the surgeon is about to use an instrument tray after a break in sterile technique, but the surgeon dismisses the technician's first quiet comment. Which safety communication action should the scrub technician take next?
- A hospital discovers that critical care, medical-surgical, and emergency units maintain separate smart infusion pump drug libraries with different concentration defaults, leading float nurses to select incorrect dosing profiles. Which system-level safety intervention best reduces this hazard?
- An outpatient interventional radiology suite performs a procedure on the wrong side of a patient after the technician verbally confirms the patient's name while positioning equipment and the physician begins immediately without pausing the room. Which Universal Protocol safeguard was most critically bypassed?
- A community hospital discovers that 18% of inpatient adverse drug events stem from omitted home anticoagulants and antihypertensives that were missing from admission orders. Which medication reconciliation practice should the safety team standardize at admission?
- A general medical-surgical unit increasingly admits patients with acute suicidal ideation while awaiting behavioral health placement. Which proactive patient safety intervention best reduces environmental self-harm risk on the unit?
- During a root cause analysis of a delayed sepsis diagnosis in an emergency department, reviewers find the initial clinician anchored on a benign viral illness diagnosis and missed worsening vital signs recorded by nursing. Which safety intervention best addresses this cognitive vulnerability?
- During closure of an abdominal laparotomy, the circulating nurse and scrub technician identify a missing laparotomy sponge on the final count, and the surgeon suggests closing the incision because the wound looks clear. Which safety protocol should the surgical team follow?
- An acute care hospital investigates four near misses in one month where physicians entered laboratory or medication orders on the wrong patient while toggling between multiple open electronic health record charts during busy rounds. Which safety technology intervention most effectively reduces these wrong-patient order-entry errors?
- A busy medical-surgical unit experiences two wrong-patient blood draw incidents in one month after phlebotomists verify identity by checking the room number on the white board and asking patients to nod when called by their last name. Which standard safety practice directly prevents this error?
- A hospital's code blue committee reviews three resuscitation delays in which float nurses and resident physicians struggled to locate epinephrine and airway supplies because each inpatient unit stocked its emergency crash carts differently. Which human factors intervention best reduces search errors during emergencies?
- An inpatient medical unit installs bed-exit alarms on every bed to reduce patient falls, yet fall rates with injury remain unchanged and nurses report frequent false alarms. Which patient safety strategy should the safety officer recommend instead?
- An inpatient medical-surgical hospital experiences three serious adverse events over two months when patients transferred from the intensive care unit arrive on general wards with missed anticoagulation holds and unclear escalation plans. Nurses and physicians currently give free-form verbal updates by phone without a shared template. Which safety intervention most reliably reduces these transfer errors?
- An outpatient clinic's laboratory calls a critical potassium result to a medical assistant at 4:45 p.m. on Friday, who jots it on a sticky note and leaves it on the ordering physician's keyboard after the physician has already left for the weekend. Which safety process change best prevents delayed follow-up of critical test results?
- A medical-surgical unit notices that several unexpected cardiopulmonary arrests occurred on night shifts even though vital sign trends showed hours of worsening tachycardia and tachypnea. Nurses report hesitating to call the rapid response team because the covering physician prefers to be paged first and sometimes criticizes unnecessary activations. Which safety system improvement best addresses this failure-to-rescue pattern?
- A hospital pharmacy safety review identifies recurring near misses where staff nearly select the wrong drug from pairs of medications with similar names, such as hydralazine and hydroxyzine, during order entry and bin picking. Which system-level safeguard best reduces this hazard?
- Six months after completing a root cause analysis for a serious inpatient medication error, a hospital safety committee discovers that the same type of error has occurred again on another unit. Which gap in the root cause analysis process most likely explains the recurrence?
- A community hospital's safety and emergency management committee needs a structured annual method to rank potential internal and external hazards—such as utility failures, cyberattacks, and severe weather—by likelihood, potential harm, and current readiness. Which proactive assessment should the committee conduct?
- A hospital safety committee reviews a near miss in which a nurse nearly drew up concentrated potassium chloride from an automated dispensing cabinet for direct intravenous push. Which system-level engineering control should the committee implement?