8 Cleaning, Disinfection, Sterilization of Medical Devices and Equipment
CIC · 40 questions
- A central sterile processing technician reports a positive biological indicator spore test from a steam sterilization cycle that included orthopedic instruments, though the internal chemical indicator inside the test pack passed. What is the immediate priority action?
- At the end of an abdominal surgery, a circulating nurse notices dried blood on reusable laparoscopic instruments that will not be transported to central sterile processing for another two hours. Which point-of-use practice should the nurse perform immediately?
- Before running the first instrument load of the morning in a dynamic-air-removal prevacuum steam sterilizer, a central sterile technician prepares a Bowie-Dick test pack. What is the primary purpose of running this test in an empty chamber each day?
- An outpatient endoscopy suite uses a reusable ortho-phthalaldehyde (OPA) bath in an automated endoscope reprocessor for flexible colonoscopes. What quality control check must staff perform before each use of the disinfectant solution?
- An outpatient gynecology clinic uses a reusable vaginal ultrasound probe covered with a single-use protective sheath for routine exams. After removing and discarding the sheath, how must the probe be reprocessed before the next patient?
- After a completed steam sterilization cycle and standard cooling period, a central sterile processing technician opens the sterilizer and notices visible moisture droplets inside wrapped surgical instrument trays. What is the required action for these wet packs?
- During a supply room audit on a surgical unit, an infection preventionist finds one wrapped sterile instrument tray with a visible water stain on its outer wrap and another intact, dry tray sterilized eight months earlier. Which action follows event-related sterility principles?
- An orthopedic operating room team asks central sterile processing to use immediate-use steam sterilization (IUSS) routinely between back-to-back cases because the facility owns only two sets of a specialized retractor. How should the infection preventionist respond?
- An ambulatory surgery center experiences a sudden schedule increase and a surgeon asks whether reusable rigid arthroscopes can undergo high-level disinfection in an automated reprocessor instead of sterilization between cases. The arthroscope is heat-stable, its IFU requires sterilization, and validated sterilization is available. How should the infection preventionist respond based on the Spaulding classification?
- During a sterile processing audit, an infection preventionist observes a technician placing visibly soiled stainless-steel surgical forceps directly into a liquid chemical sterilant bath without manual washing. Why must this practice be stopped immediately?
- An outpatient gastrointestinal clinic completes high-level disinfection of a flexible colonoscope in an automated endoscope reprocessor, but staff skip the final channel drying step and place the scope coiled inside a closed plastic bin overnight. Which risk does this practice create?
- A central sterile processing department runs a steam sterilization cycle containing orthopedic bone plates and screws along with a biological indicator test pack. At the end of the cycle, the physical printouts and external chemical indicators pass, and the operating room requests the implants immediately. How should the sterile processing technician respond?
- A surgical scrub nurse opens a wrapped instrument tray and sees that the external indicator tape changed color, but the internal chemical indicator strip in the center of the tray did not reach its pass endpoint. What action should the nurse take?
- A central sterile processing technician receives a flexible gastroscope in the decontamination area after an outpatient procedure and prepares to begin reprocessing. Before immersing the gastroscope in enzymatic detergent for manual brushing, which step must the technician perform first?
- In the decontamination area of central sterile processing, a technician holds a soiled, lumened suction tip under a running faucet and scrubs the channel vigorously above the waterline, creating visible mist and droplets. Which manual cleaning practice should the technician use instead?
- A central sterile processing department is transitioning rigid laparoscopes from steam sterilization to a low-temperature hydrogen peroxide gas plasma sterilizer. Which packaging material change is required before processing these instruments?
- An outpatient primary care clinic is updating its reprocessing policy for reusable blood pressure cuffs and stethoscopes that contact only intact skin between routine patient visits. Under the Spaulding classification system, how should these items be categorized and reprocessed?
- In the decontamination area of central sterile processing, a technician prepares to manually rinse reusable surgical hemostats coated with fresh blood before placing them into an enzymatic detergent bath. Which water temperature practice should the technician follow?
- During a decontamination and assembly audit in central sterile processing, an infection preventionist reviews surgical instrument trays being prepared for steam sterilization. How must hinged instruments such as hemostats and needle holders be positioned?
- A surgical technologist opens a wrapped instrument tray and sees that the external autoclave tape stripes have turned dark, but notices no internal chemical indicator was placed inside the tray. How should the infection preventionist advise the team?
- Immediately after a steam sterilizer door opens at the end of a cycle, a sterile processing technician plans to transfer warm, freshly sterilized wrapped instrument trays onto cool stainless-steel storage carts using bare hands. Why must the infection preventionist instruct the technician to leave the trays undisturbed on the sterilizer rack until cooled?
- To cut supply expenses, an ambulatory surgery center manager proposes having central sterile processing clean and steam-sterilize single-use laparoscopic trocars previously used on patients labeled 'Single Use Only' by the manufacturer. How should the infection preventionist respond?
- During central sterile processing rounds, an infection preventionist observes a technician stacking paper-plastic peel pouches flat on top of one another in dense piles inside a steam sterilizer cart. Why must this loading practice be corrected?
- After an outpatient orthopedic procedure, a surgical technologist prepares to move blood-soiled reusable instruments from the procedure room down a public hallway to the central sterile processing decontamination area. Which transport method aligns with infection prevention and OSHA standards?
- A central sterile processing department uses an ethylene oxide (EtO) sterilizer for heat- and moisture-sensitive surgical instruments. Which biological indicator organism is required to verify lethality of the EtO sterilization cycle?
- An outpatient dental clinic attached to a community health center is updating its reprocessing protocol for reusable high-speed dental handpieces that connect to air and water lines. How must these handpieces be reprocessed between patients?
- A newly hired central sterile processing technician asks why the department must run biological indicators in steam sterilizers when every load already produces a physical temperature-time printout and includes chemical indicator strips. How should the infection preventionist explain the unique role of biological indicators?
- A newly hired central sterile processing technician prepares a biological indicator process challenge device to monitor a full load of wrapped surgical instrument trays in a steam sterilizer. Where inside the sterilizer chamber must the technician place this test pack?
- An outpatient endoscopy clinic uses reusable flexible colonoscopes and reusable endoscopic biopsy forceps during routine screening procedures. After thorough manual cleaning, the colonoscopes undergo high-level disinfection in an automated endoscope reprocessor. How must the reusable biopsy forceps be reprocessed before the next patient?
- A central sterile processing technician completes an ethylene oxide sterilization cycle for heat-sensitive neurosurgical catheters and sees that the physical cycle printout and chemical indicator have passed. What step must occur before releasing these catheters to the operating room?
- In the clean assembly area of central sterile processing, a technician inspects a dried reusable surgical clamp under lighted magnification before wrapping and notices dried bioburden inside the box lock. What action is required?
- A central sterile processing department relies on automated washer-disinfectors to clean surgical instruments before wrapping and steam sterilization. During a quality audit, the infection preventionist learns that staff only inspect instruments visually after the cycle and run no mechanical cleaning checks. The facility’s validated quality-assurance protocol requires daily washer cleaning verification. What is its purpose?
- During operating room rounds, an infection preventionist observes an anesthesia technician wiping a used reusable metal laryngoscope blade with a 70% isopropyl alcohol pad and placing it unwrapped back into the anesthesia cart drawer. Which reprocessing standard must the infection preventionist enforce?
- In an operating room, a surgical technologist prepares to keep blood-soiled stainless-steel instruments moist during a brief delay before transport to decontamination. Which solution must be avoided because it causes pitting and corrosion of instrument surfaces?
- A central sterile processing technician prepares to load a steam sterilizer cart with heavy stainless-steel orthopedic instrument trays and lighter wrapped linen packs for the same cycle. How should the technician arrange the items on the sterilizer cart?
- A central sterile processing technician receives a multi-piece reusable laparoscopic trocar assembly with removable gaskets and inner cannula in the decontamination area. How must the technician prepare this device before manual cleaning and sterilization?
- A central sterile processing technician places a biological indicator vial from a steam sterilizer load into the incubator at the end of a cycle. Which additional step is required to validate that the biological indicator test itself is working properly?
- A newly hired endoscopy technician places a used flexible gastroscope directly into an automated endoscope reprocessor without manual brushing or channel flushing, assuming the machine's pre-wash cycle replaces manual decontamination. This AER’s validated IFU requires prior manual brushing and channel flushing. This machine’s prewash does not replace its required manual cleaning; follow the validated endoscope/AER process. Why must the infection preventionist intervene?
- An outpatient clinic runs low on its routine hospital surface disinfectant wipes and a medical assistant proposes wiping exam tables with ortho-phthalaldehyde (OPA) solution poured from the endoscopy soaking basin. Why must the infection preventionist prohibit this practice?
- During a central sterile processing audit, an infection preventionist observes a technician mixing an enzymatic detergent into hot tap water at 65 degrees Celsius by eye without a measuring dispenser. Why must the technician follow the manufacturer's instructions for use regarding dilution and water temperature?