3 Store Materials with Hazard
CHMM · 28 questions
- A laboratory technician at a manufacturing facility generates spent ignitable solvent at a benchtop workstation and collects it in a 5-gallon safety carboy located next to the hood under RCRA satellite accumulation rules (40 CFR 262.15). Which practice keeps the satellite accumulation container in compliance during routine operations?
- A paint-manufacturing facility stores 55-gallon steel drums of Class 1B flammable solvent inside a dedicated flammable storage room and dispenses solvent from a grounded drum into a smaller metal safety can. To prevent an electrostatic discharge spark from igniting flammable vapors during transfer, what physical connection must the operator establish before opening the drum valve?
- A manufacturing plant operates a RCRA central accumulation area storing 55-gallon steel drums of ignitable and toxic hazardous waste on spill-containment pallets. During a routine walk-through, the EHS coordinator notices drums staged tightly wall-to-wall with no walking path between rows. Under RCRA container storage standards, what condition must be restored immediately?
- A manufacturing plant is reorganizing its indoor chemical warehouse and needs to store drums of concentrated nitric acid alongside drums of isopropyl alcohol. Both liquids are currently scheduled to sit on the same four-drum spill containment pallet to save floor space. Why must the warehouse supervisor separate these two materials into different containment areas?
- An EHS specialist inspects a Large Quantity Generator's central accumulation area and finds newly filled 55-gallon drums of spent ignitable solvent labeled only with the words Hazardous Waste. Under 40 CFR 262.17(a)(5), what additional information must be clearly marked and visible on each drum?
- An EHS manager at a manufacturing plant classified as a RCRA Large Quantity Generator is siting a new outdoor central accumulation area for 55-gallon drums of ignitable solvent waste. Under 40 CFR 262.17(a)(1)(vi), what minimum distance must separate those containers from the facility property line unless the local fire authority grants written approval?
- An EHS specialist manages a RCRA Large Quantity Generator central accumulation area holding 55-gallon steel drums of corrosive and ignitable wastes awaiting off-site shipment. Under 40 CFR 262.17(a)(1)(v), how often must the facility inspect these container storage areas for leaks and deterioration?
- A permitted hazardous waste storage facility plans to store twenty 55-gallon drums of liquid waste inside a diked concrete containment bay. Under 40 CFR 264.175, what minimum spill-containment volume must the bay hold to satisfy federal secondary containment capacity rules?
- A manufacturing facility plans to store sealed drums of flammable and corrosive raw materials in a covered outdoor pad adjacent to a public alley. What combination of site security and hazard communication controls should the facility implement for this storage area?
- A specialty coatings warehouse stores bulk totes of flammable resins, organic peroxides, and water-reactive catalysts inside a dedicated chemical storage building. Local fire officials ask the facility to post exterior building signage that communicates acute health, flammability, instability, and special hazards to arriving responders at a glance. Which hazard identification system meets this requirement?
- A machining department accumulates spent ignitable solvent at a workstation in a RCRA Satellite Accumulation Area. During a morning check, the operator notices that a second 55-gallon drum at the same point of generation has just pushed the total accumulated volume past 55 gallons. Under 40 CFR 262.15(a)(6), what must the facility do?
- A RCRA Large Quantity Generator accumulates drummed spent corrosive waste in its central accumulation area, and a carrier delay leaves several drums on-site as the 90-day accumulation limit approaches. Under 40 CFR 262.17, what must the facility do before day 90 expires to stay exempt from hazardous waste storage permitting?
- A paint-blending shop installs a new listed flammable liquid storage cabinet inside its production bay to hold 1-gallon and 5-gallon metal cans of acetone and toluene, both Category 2 flammable liquids. Under OSHA 29 CFR 1910.106(d)(3), what storage rule applies to this cabinet?
- A metal-fabrication plant stores spare compressed oxygen cylinders and acetylene fuel-gas cylinders in the same indoor maintenance storage bay while awaiting use. Under OSHA 29 CFR 1910.253(b)(4)(iii), how must the facility separate these cylinders in storage?
- A composite-materials manufacturer receives drums of methyl ethyl ketone peroxide catalyst for resin curing. Which storage arrangement should the warehouse manager establish to prevent thermal runaway?
- A maintenance shop receives full compressed argon and nitrogen cylinders for welding and inerting operations and needs to store them in an indoor cylinder rack until needed. Which storage practice is required under OSHA 29 CFR 1910.101?
- A manufacturing plant classified as a RCRA Large Quantity Generator accumulates spent corrosive liquid in a stationary 2,500-gallon indoor tank rather than in drums. Under 40 CFR 262.17(a)(5)(ii), how must the facility demonstrate that the waste in the tank is not accumulated beyond 90 days?
- A semiconductor fabrication plant generates spent hydrofluoric acid etching solution classified as RCRA hazardous waste and needs new 55-gallon drums for its central accumulation area. Which container choice satisfies federal RCRA container-compatibility rules?
- A maintenance shop places a 55-gallon satellite accumulation drum for spent solvent in an unlocked corridor two rooms away from the parts-cleaning sink because floor space near the sink is tight. Why does this placement violate RCRA satellite accumulation rules under 40 CFR 262.15?
- A specialty chemical warehouse receives sealed steel drums of a Division 4.3 dangerous-when-wet solid that evolves flammable hydrogen gas upon contact with moisture. Which storage arrangement should the warehouse manager establish?
- A quality-control laboratory stores several bottles of uninhibited tetrahydrofuran and ethyl ether in a flammable storage cabinet, and some containers have been on the shelf for over a year without inspection. During a safety walk-through, the EHS specialist notes white crystalline residue around one cap. What storage management program should the facility implement for peroxide-forming chemicals?
- A metal-plating warehouse stores 55-gallon steel drums of sodium cyanide solid alongside 15-gallon polyethylene carboys of concentrated hydrochloric acid in the same diked storage room. Why must the warehouse manager physically segregate these two materials into separate containment areas?
- A metal-finishing facility operating as a RCRA Large Quantity Generator places a new 55-gallon steel drum in its central accumulation area to collect spent acidic rinsewater. Along with the accumulation start date, what information must be marked on the container label?
- A chemical manufacturing plant accumulates spent concentrated nitric acid and needs an empty 55-gallon drum in its central accumulation area. Operators find a steel drum that previously held organic solvent residue and still has a strong odor inside. What must the facility do under RCRA 40 CFR 262.16(b)(2)(v) or 262.17(a)(1)(vii), depending on generator category, before using that drum for the nitric acid?
- A permitted hazardous waste storage facility stores drummed ignitable and corrosive wastes in an outdoor fenced yard adjacent to an industrial park road. Under federal RCRA security standards in 40 CFR 264.14, what combination of controls is required to prevent unknowing or unauthorized entry?
- A manufacturing facility operating as a RCRA Large Quantity Generator accumulates spent ignitable solvent in an aboveground 5,000-gallon steel tank system equipped with secondary containment and level gauges, and no leak-detection alternative is in use. How often must the facility inspect the tank's overfill controls, aboveground piping, and containment area?
- During a walk-through of a RCRA Large Quantity Generator central accumulation area, an EHS specialist notices a 55-gallon steel drum of spent ignitable solvent fitted with a metal funnel whose hinged lid is propped open for convenience across the shift. Which RCRA container management standard is the facility violating under 40 CFR 262.17?
- A specialty coatings plant plans to store 55-gallon drums of Category 2 flammable solvents inside a dedicated room in its main manufacturing building. Which room design satisfies OSHA 29 CFR 1910.106(d)(4) indoor flammable storage room requirements?