- A radionuclide used in a calibration laboratory has a physical half-life of exactly 10.0 hours. What is its exponential decay constant?
- A narrow beam of monoenergetic gamma photons passes through 2.0 cm of lead, where the half-value layer (HVL) is 0.50 cm. What fraction of the original beam intensity is transmitted through the shield?
- A gamma source produces an unshielded dose rate of 160 mrem/hr at a workstation. If the half-value layer (HVL) of lead for this photon energy is 0.40 cm, what minimum thickness of lead is needed to reduce the dose rate at the workstation to 10 mrem/hr?
- For a monoenergetic gamma beam, a shielding material has a linear attenuation coefficient of 0.231 per centimeter. What is the half-value layer (HVL) of this material?
- An unshielded gamma source produces an exposure rate of 400 mR/hr at an operator station. If a technologist places a shield equivalent to 2 half-value layers (HVLs) of lead and 1 tenth-value layer (TVL) of concrete in the beam, what is the resulting exposure rate under narrow-beam conditions?
- For a specific gamma-ray energy, ordinary concrete has a half-value layer (HVL) of 6.0 cm. Approximately what thickness of concrete equals one tenth-value layer (TVL) for this same gamma energy?
- A radiation shield requires a mass thickness of 22.6 g/cm² of lead to adequately attenuate a gamma beam. Given that the density of lead is 11.3 g/cm³, what physical thickness of lead sheet is required?
- A shipment of Technetium-99m (physical half-life 6.0 hours) arrives at a nuclear medicine clinic with a measured activity of 40 mCi. If 18 hours elapsed between calibration at the radiopharmacy and arrival at the clinic, what was the activity at calibration?
- A medical research sample contains 640 mCi of Sodium-24, which has a physical half-life of 15.0 hours. How many hours must the sample be held in decay-in-storage for its activity to decrease to 5.0 mCi?
- A technologist measures an unshielded gamma exposure rate of 360 mR/hr at 1.0 meter from a small point source. At what minimum distance from the source will the exposure rate drop to 10 mR/hr, assuming negligible air attenuation?
- A sealed gamma calibration source has an activity of 2.0 Ci and a specific gamma-ray constant of 1.3 R·m²/(Ci·hr). Neglecting air attenuation and scatter, what is the unshielded exposure rate at a distance of 2.0 meters from the source?
- A radiochemistry technician pipettes 2.0 mL of a stock solution with an activity concentration of 4.5 × 10^-2 µCi/mL into a volumetric flask and dilutes it to a total volume of 100 mL. What is the activity concentration of the final diluted solution?
- A narrow, monoenergetic gamma beam produces an unshielded exposure rate of 200 mR/hr. Placing a 6.0 cm thick shield in the beam reduces the exposure rate to 25 mR/hr. Using ln(2) equals 0.693, what is the linear attenuation coefficient of the shielding material?