(official category 17; see category page)
RPT · 12 questions
- A laboratory handles volatile radioiodine (I-131) in a fume hood exhaust system equipped with a pre-filter and a HEPA filter. Why must an activated charcoal adsorber also be installed downstream of the HEPA filter?
- A technician works inside a glovebox room where localized grinding of depleted uranium can create steep airborne concentration gradients. Which air-sampling method provides the most representative estimate of that individual worker's inhalation intake?
- A technician runs a portable air sampler at a constant flow rate of 50 liters per minute for 20 minutes in a work area and collects 3.0 x 10^-4 microcuries of a long-lived alpha emitter on the filter. Assuming 100 percent collection efficiency, what is the average airborne concentration?
- When designing or verifying ventilation for a facility handling unsealed radioactive powders, which airflow pattern best prevents airborne contamination from spreading into clean occupied corridors?
- Airborne sampling in a work room shows an average radionuclide concentration of 0.4 DAC, which is below 1 DAC, and an unmasked worker is scheduled to spend 40 hours there during the week. Under NRC 10 CFR 20.1003 and 20.1902(d), why must this room be posted as an Airborne Radioactivity Area?
- Under NRC 10 CFR 20.1703 respiratory protection requirements, why is a worker with facial hair in the facepiece sealing surface prohibited from wearing a tight-fitting negative-pressure respirator?
- A technician must enter an area with a particulate airborne concentration of 25 DAC while wearing a properly fit-tested, full-facepiece negative-pressure air-purifying respirator (APF of 50 under 10 CFR 20 Appendix A). What is the effective airborne concentration inside the facepiece?
- Why are High-Efficiency Particulate Air (HEPA) filters in radiological ventilation systems rated and challenged using 0.3-micrometer aerosols rather than smaller 0.01-micrometer particles?
- A facility plans to machine lightly contaminated metal components in a shop where airborne alpha activity could exceed occupational limits. Under NRC 10 CFR 20.1701, which control approach must the licensee prioritize first to limit airborne concentrations?
- A facility's radiological exhaust ventilation bank uses a coarse fibrous pre-filter immediately upstream of the primary High-Efficiency Particulate Air (HEPA) filter. What is the primary operational purpose of this pre-filter?
- Before entering an Airborne Radioactivity Area wearing a tight-fitting negative-pressure air-purifying respirator, a worker performs positive- and negative-pressure user seal checks. What is the purpose of this pre-entry check compared with the annual fit test?
- A technician must enter a containment room where airborne Xenon-133, a radioactive noble gas, exceeds derived air concentration limits. Why is a standard negative-pressure air-purifying respirator equipped only with P100 particulate filters inadequate for this entry?