(official category 10; see category page)
RPT · 13 questions
- A technician needs to retrieve a small, activated metal bolt from a reactor cavity floor where the contact dose rate is 800 mrem/hr, while the dose rate at 1 meter is 4 mrem/hr. Which ALARA practice most effectively reduces the technician's extremity and whole-body dose during retrieval?
- A technologist must perform a brief visual inspection of a valve located near an unshielded gamma source, and no temporary shielding is available. Applying ALARA principles for external exposure, which action provides the greatest immediate dose reduction if the inspection duration is fixed?
- Before a 10-minute valve inspection in a 60 mrem/hr area, a crew considers spending 20 minutes in the same 60 mrem/hr area to hang temporary lead blankets that would reduce the field to 15 mrem/hr. Applying ALARA principles, what should the radiation protection technician recommend?
- A maintenance crew must perform an intricate valve repair inside a high-radiation cubicle where space is tight and protective gear restricts dexterity. Which pre-job ALARA action most effectively reduces worker stay time during the actual entry?
- A maintenance crew must unbolt and replace a leaking valve on a process line that normally carries radioactive resin slurry. Which pre-job ALARA measure most effectively lowers the radiation field for the entire work crew?
- A two-person crew must perform a multi-step repair in a pump room where a localized hot spot produces 120 mrem/hr, while an adjacent shielded corner reads 3 mrem/hr. While one worker waits for tools or instructions during brief pauses, what ALARA practice best minimizes collective dose?
- A crew must perform a 90-minute valve repair inside a 150 mrem/hr cubicle while a health physics technician and a maintenance supervisor oversee the work. Which ALARA measure best eliminates unnecessary exposure for the two oversight personnel?
- A crew must repair a valve in a 200 mrem/hr gamma field where airborne concentration is 0.5 DAC. Wearing full-face respirators would double the repair time because of reduced visibility and communication. Applying ALARA TEDE optimization, what should the planner do?
- Why does a facility ALARA program establish administrative dose investigation levels well below the annual regulatory limits in 10 CFR 20.1201?
- A maintenance crew must replace a gasket on a radioactive filter housing that has a localized 400 mrem/hr hot spot on its drain valve, while the upper flange reads 25 mrem/hr. Which pre-job ALARA action best reduces collective dose during the repair?
- A maintenance crew needs to replace a sensor inside a cyclotron vault immediately after an irradiation run, where short-lived air and target activation products create a 120 mrem/hr field. If the repair is not urgent, which ALARA action most effectively reduces collective dose without adding shielding?
- A planner proposes assigning four technicians for 15 minutes each instead of two technicians for 30 minutes each in a uniform 100 mrem/hr field, without changing tools or shielding. How does this staffing change affect individual dose versus collective dose?
- After a routine steam-generator inspection finishes, the health physics supervisor notes that the crew's actual collective dose was 4.2 person-rem compared with the pre-job ALARA estimate of 1.8 person-rem. Which ALARA program action should be taken next?