At a container terminal, a quay-crane HMI and its PLC are in the same VLAN, both access ports are up, and a trunk sits between them. The trunk allowed list omits that VLAN. Which fault explains the outage?
Select an answer to reveal the explanation.
Short Explanation
The rooms are fine and the corridor between them refuses this floor's traffic. You left the crane VLAN off the trunk allowed list, so the HMI and the PLC never meet even though both access ports are up. A port that was err-disabled would look dark on the access port itself.
Full Explanation
Two access ports in the same VLAN can exchange frames across a trunk only when that VLAN is allowed on the trunk. The quay-crane HMI and PLC are up, in the crane VLAN, with a trunk between them, and the allowed list omits that VLAN. Frames for the VLAN stop at the trunk. That is the outage, and both access ports can stay up and forwarding local devices the whole time. Port security in shutdown mode would err-disable the PLC port, and the stem says that port is up, so an err-disable does not fit. A wrong access VLAN on the HMI would mean the two devices are not in the same VLAN. The stem says they are, so the fault is not a mismatched access assignment. Shutting the switched virtual interface removes the routed address for the VLAN. It does not delete the VLAN from a trunk's allowed list, and it does not stop Layer 2 forwarding of a VLAN the trunk actually allows. Exam caveat: if the HMI and PLC had been placed in different VLANs on purpose, they would need a routed path. This stem keeps them in one VLAN and shows the trunk dropping it. Operational check: show interfaces trunk should omit the crane VLAN from the allowed list while both access ports remain connected.