A substation vendor account on the engineering workstation is still active months after the outage that justified it. Which practice closes that gap?
Select an answer to reveal the explanation.
Short Explanation
A contractor badge that still opens the gate months later is a badge you forgot to take back. Expire that substation vendor account when the outage window ends and confirm the login no longer works. Leaving it ready for the next phone call keeps a stranger on the list.
Full Explanation
A vendor account is a credential for a named window of work, not a permanent seat on the engineering workstation. Months after the outage, that account is still active, so the person or anyone who holds the password can still use a login the outage no longer justifies. Disabling or expiring it when the window ends closes the gap. Leaving it enabled and sharing the password with every technician who might call the vendor multiplies the secret and keeps the access alive. Speed on the next phone call is not a reason to skip expiration. Publishing the workstation address so the vendor can connect without an account removes identification entirely. Reachability without a credential is a wider gap than a stale account. Replacing the named account with one shared password on the relay panel door throws away the name on the login and posts the secret where a panel visitor can read it. A shared writing on a door does not expire when the outage ends. Exam caveat: expiring the account does not delete drawings the plant should keep. Those belong in the substation archive, not in a live vendor login. Operational check: the account should fail a test login after the window, and the access record should show the expiration date that matches the outage ticket.