After a trunk cleanup, a control-room HMI cannot reach a robot cell, but PLCs and drives on the cell switch still communicate. The uplink trunk no longer allows the HMI VLAN. Which explanation fits?
Select an answer to reveal the explanation.
Short Explanation
A hallway deleted from the building map will not carry you to the control room, even while people inside the cell still talk. The trunk no longer allows the HMI VLAN, so that VLAN stops before the control room. A failed gateway story that also kills cell traffic does not match a cell that is still running.
Full Explanation
A trunk carries only the VLANs its allowed list still names. After the cleanup, the HMI VLAN is no longer on that list, so frames for the HMI stop at the cell switch and the control room is no longer in that broadcast domain. Devices on the cell switch stay in the VLAN locally, which is why the PLCs and drives still communicate. That matches the symptom exactly. A distant firewall ACL can block a routed path, but it is not required to explain this break, and it is not true that dropping a VLAN from the trunk cannot separate the HMI. The trunk list is sufficient to isolate the far side. A failed default gateway is a routing problem. Hosts in the same VLAN on the same switch do not need that gateway to talk, and the stem says they still do. The gateway story also claims the cell went quiet, which contradicts the working drives. Port security disabling the HMI port would affect that port. It would not, by itself, be why drives on the cell switch lose their PLCs, and the stem says those drives have not lost the PLCs. Exam caveat: if the HMI were supposed to reach the cell through a routed hop instead of the same VLAN, a different filter could matter. This stem gives a trunk that dropped the VLAN and a cell that still runs. Operational check: restore the HMI VLAN on the trunk allowed list, confirm the HMI can reach its PLC, and confirm a VLAN that should not cross is still absent.