A well-logging service uses a deuterium-tritium (D-T) accelerator tube rather than an Americium-Beryllium (Am-Be) sealed source to generate fast neutrons. What is the primary radiological safety advantage of the D-T neutron generator during transport and storage?
Select an answer to reveal the explanation.
Short Explanation
An Am-Be source never sleeps—it emits neutrons around the clock until its Americium decays away, so you have to haul heavy shielding everywhere. A D-T generator only makes neutrons when the accelerator is switched on, so turning off the power turns off the neutron beam. The trap is thinking a D-T tube has zero radioactivity inside; it still holds a small tritium inventory, even with the beam off.
Full Explanation
A deuterium-tritium (D-T) neutron generator accelerates deuterium ions into a tritium-loaded target to drive the D-T fusion reaction, yielding 14.1 MeV neutrons. Selecting "It stops emitting neutrons completely whenever high voltage is turned off" identifies the decisive operational safety advantage over isotopic Am-Be sources, which emit neutrons continuously via alpha-beryllium reactions and require bulky shielding during storage and transport. Choosing "It emits only low-energy thermal neutrons that require no hydrogenous moderation" is incorrect because D-T fusion produces high-energy 14.1 MeV fast neutrons that require substantial moderation and shielding while operating. Picking "It produces neutrons through spontaneous fission with a half-life under one hour" describes neither a D-T accelerator nor Am-Be, and instead mischaracterizes spontaneous-fission nuclides such as Californium-252. Selecting "It contains no radioactive tritium gas inside the sealed accelerator target" is false because the tube houses a sealed tritium target that represents a potential beta-contamination hazard if ruptured. As a caveat, structural materials around the target can become neutron-activated after prolonged high-output operation and emit residual gamma radiation after shutdown. As an operational check, perform a gamma and neutron survey around the housing after de-energizing to confirm zero neutron output and check for activation.
Prefer to study offline? Printable PDF study book + test engine ($7.50, unofficial). These questions stay free here.