A maintenance technician uses a calibrated four-gas meter to test a nitrogen-purged process vessel before entry and records an oxygen concentration of 18.2 percent with zero flammable gas or toxic vapor readings. Because no toxic gas is detected, the technician asks to enter using a half-mask air-purifying respirator with organic vapor cartridges. How must the EHS specialist respond under OSHA 29 CFR 1910.134 and 1910.146?
Select an answer to reveal the explanation.
Short Explanation
A cartridge respirator is like a coffee filter—it only strains out contaminants, so it cannot create oxygen out of thin air for you. The trap here is seeing zero toxic gas and forgetting that 18.2 percent oxygen is already oxygen-deficient. You must prohibit air-purifying respirators and require supplied-air or SCBA protection.
Full Explanation
Under OSHA 29 CFR 1910.146 and 1910.134, less than 19.5 percent oxygen is oxygen-deficient. All oxygen-deficient atmospheres are IDLH unless the employer demonstrates oxygen can be maintained under 1910.134 Table II, 16.0 to 19.5 percent below 3,001 feet, when any atmosphere-supplying respirator may be used. At 18.2 percent, air-purifying respirators remain prohibited because they filter contaminants but cannot supply oxygen, so the specialist must Prohibit air-purifying respirator use and require supplied-air or SCBA protection for oxygen deficiency. Approving entry with the air-purifying respirator because toxic gas readings are zero is dangerous because nitrogen alone can cause asphyxiation. Authorizing entry with a full-facepiece air-purifying respirator for higher protection fails for the same reason, as higher protection factor still depends on ambient oxygen. Permitting entry without protection after five minutes of fan ventilation is unsafe because time alone never replaces calibrated retesting. An auxiliary escape cylinder on a supplied-air respirator is required only when the atmosphere is IDLH, not when the Table II exception is met. A permit may authorize entry below 19.5 percent with atmosphere-supplying respirators; OSHA does not require the permit to block entry until oxygen is 19.5 to 23.5 percent.
Prefer to study offline? Printable PDF study book + test engine ($7.50, unofficial). These questions stay free here.