A research lab wants the main number to play a closed greeting on a public holiday. The daytime auto attendant already works the rest of the year. A macro already runs on a lab room device. What should they configure?
Select an answer to reveal the explanation.
Short Explanation
A holiday greeting is a date on the shop calendar, not a script taped to one machine in the back room. You put the holiday on the auto attendant schedule so the main number plays the closed greeting. A device macro never answers the public number.
Full Explanation
An auto attendant schedule is what selects a holiday greeting on the number it answers. The daytime menu already works the rest of the year, so the lab should put the holiday on the auto attendant schedule and let the main number play the closed greeting that day. A new call permission named for that holiday allows or blocks a call type. A permission does not play a closed greeting when someone dials the lab main number. A translation pattern that removes the main number rewrites or strips digits. Stripping digits does not select a greeting, and the caller still needs to reach the attendant. The closed greeting inside the room device macro runs on that device through the local device API. A macro running on the lab system does not answer the public number, so it cannot play the holiday message to outside callers. Exam caveat: holidays, after hours, and business hours are schedule choices on the attendant, not separate dial-plan objects. Operational check: add the holiday date to the attendant schedule, place a test call as if that date were active, and confirm the closed greeting plays while a normal day still plays the daytime menu.