A bottling plant already has paging rules and an empty metrics store. The conveyor API was never instrumented, and container images are already scanned. Which element is missing?
Select an answer to reveal the explanation.
Short Explanation
You’ve got the alarm bell wired, but the sensor was left out of the install. Add monitoring that collects health and error signals from the conveyor API into the metrics store. More paging rules for metrics the API does not emit, another scan of images already scanned before release, or a playbook without an incoming signal cannot create that sensor.
Full Explanation
The plant can write paging rules and scan images, but it cannot tell that the conveyor API is down because nothing collects health or error signals from it, leaving the metrics store empty. Monitoring that collects those signals into the metrics store is the missing element. More paging rules aimed at conveyor metrics the API does not emit are a poor fit: there are no metrics for those rules to act on. Another container-image scan is also a poor fit because the pipeline already scans images before release, and scanning again does not make the API report its health. A response playbook with no incoming signal cannot detect that the API is down or begin a response; the signal must exist first. Exam caveat: Existing paging rules can fire once signals exist, and alerting is the gap only when metrics are already arriving but nobody is being paged. Practical check: Generate a lab error on the conveyor API, confirm a metric arrives in the store, and then confirm the existing paging rule can see that metric.