A utility crew excavates a trench 8 feet deep in Type C soil and plans to slope both walls uniformly at the OSHA maximum allowable slope of 1.5 horizontal to 1 vertical without shoring. If the trench bottom is 4 feet wide, what is the total width at the top of the trench?
Select an answer to reveal the explanation.
Short Explanation
Sloping a trench widens both sides, not just one, so you have to double the horizontal setback before adding the floor width. The trap is calculating the setback for a single wall or forgetting the 4-foot trench bottom, which leaves your excavation far too narrow for Type C soil.
Full Explanation
In Type C soil, OSHA 29 CFR 1926 Subpart P Appendix B specifies a maximum allowable slope of 1.5 horizontal to 1 vertical, meaning each foot of vertical depth requires 1.5 feet of horizontal setback on each sloped wall. For an 8-foot-deep trench, one wall steps back 1.5 times 8, which equals 12 feet; sloping both walls uniformly adds 12 feet on the left and 12 feet on the right for 24 feet of total setback, plus the 4-foot bottom width, yielding 28 feet at the top. Selecting 16 feet is a common error that adds only one wall's 12-foot setback to the 4-foot bottom, leaving the opposite wall dangerously vertical. Selecting 20 feet mistakenly applies a 1:1 slope (8 feet per wall plus 4 feet bottom), which is permitted for Type B soil rather than Type C soil. Selecting 24 feet correctly calculates the combined 24-foot setback for both walls but forgets to include the 4-foot width of the trench floor. Caveat: if water seepage, fissured soil, or nearby vibration is present, a competent person must re-evaluate the excavation and consider shoring or a trench box instead of relying on standard sloping alone. Operational check: measure the top opening with a tape measure from edge to edge before any worker enters the trench.
Prefer to study offline? Printable PDF study book + test engine ($7.50, unofficial). These questions stay free here.