Quiz 4 Question 8 of 20

After an internal audit finds that a final-inspection vision sensor was misconfigured for three weeks, the production manager submits a corrective action plan that fixes the sensor recipe and retrains technicians, but does not address units already in the warehouse. Why should the auditor reject closure of this response?

Select an answer to reveal the explanation.