A fleet maintenance facility sends a sample of accumulated used lubricating oil for pre-shipment analysis, and the laboratory reports a total halogen concentration of 2,400 parts per million. Under RCRA used oil regulations in 40 CFR 279.10(b)(1)(ii), how must the facility manage this batch?
Select an answer to reveal the explanation.
Short Explanation
When your used oil hits 2,400 ppm total halogens, you are well over the 1,000 ppm line that triggers the presumption. Manage as hazardous waste unless you rebut mixing with halogenated hazardous waste listed in 40 CFR 261 Subpart D. Don't dilute it or burn it as used oil until you have proven it does not contain hazardous waste.
Full Explanation
Under 40 CFR 279.10(b)(1)(ii), used oil containing more than 1,000 parts per million total halogens is presumed to have been mixed with halogenated hazardous waste, so at 2,400 ppm the facility must Manage as hazardous waste unless you rebut mixing with halogenated hazardous waste listed in 40 CFR 261 Subpart D. To rebut the presumption you must demonstrate that the used oil does not contain hazardous waste, using analytical testing or process knowledge to show halogens come from non-listed sources such as chlorinated additives rather than F001 or F002 spent solvents. Blending the batch with virgin diesel fuel to dilute halogens below the threshold is impermissible dilution and does not remove the presumption or authorize management under Part 279 as used oil. Shipping the batch directly for burning in an uncontrolled space-heater as off-specification oil violates Part 279 because oil subject to the unrebutted presumption cannot be burned as used-oil fuel and must be manifested as hazardous waste. Discarding the oil into the municipal sanitary sewer after an oil-water separator violates RCRA disposal requirements and Clean Water Act pretreatment prohibitions on discharge of used oil to POTWs.
Prefer to study offline? Printable PDF study book + test engine ($7.50, unofficial). These questions stay free here.