A dental practice receives a new batch of monthly personnel radiation dosimeters along with a designated control badge. Where should the dental assistant store the control badge during the monitoring period?
Select an answer to reveal the explanation.
Short Explanation
A control dosimeter works like a zeroed scale—if you leave it near an X-ray room, it picks up stray scatter and skews everyone's monthly dose report. Keep that control badge in a radiation-free area so it only measures normal background and shipping exposure.
Full Explanation
In a radiation-free office area away from all dental X-ray equipment ensures the control badge records only natural background radiation and any incidental exposure accumulated during shipping. The dosimetry laboratory subtracts the control badge reading from each staff member's badge so occupational dose reports reflect only workplace X-ray exposure. Clipped to the wall directly behind the patient chair in the main X-ray room places the control badge in the primary beam path, artificially inflating the baseline reading and hiding real staff exposure. Inside the lead-lined tubehead storage cabinet next to the panoramic unit still risks scatter exposure whenever the panoramic machine operates. Pinned beside the exposure switch just outside the operatory doorway exposes the control badge to potential scatter radiation at the control station rather than keeping it at true background levels. As a monitoring caveat, never use the control badge as a spare personal badge for a new or temporary employee. For a concrete operational check, store the control badge in an administrative office or break room away from operatory walls, and return it in the same mailing envelope with all worn staff badges at the end of the cycle.
Prefer to study offline? Printable PDF study book + test engine ($7.50, unofficial). These questions stay free here.