A grocery chain runs checkout pods on shared cloud-native nodes. Pods on the same node talk over virtual interfaces that an upstream appliance never receives. Which design can enforce those pod-to-pod flows?
Select an answer to reveal the explanation.
Short Explanation
Same-node pod traffic is a hallway talk the gate guard never hears. You enforce it with an eBPF program on the node that hosts the pods. An upstream appliance, a storefront web firewall, or an internet-edge sensor never sees those virtual interfaces.
Full Explanation
Pods on one node exchange packets on virtual interfaces that never leave the host, so an upstream appliance cannot allow or deny what it does not receive. An eBPF program on the node sees those interfaces and applies the pod policy in the kernel, which is where this flow actually exists. A storefront parser and an edge alert sensor sit on other paths and do not receive the same-node packets. An eBPF program on the node that enforces policy on that node's pod virtual interfaces is the design that meets this requirement. A stateful appliance upstream of the node that only sees packets after they exit the host is the wrong fit because packets between two pods on one node never arrive there, so its allow and deny rules have nothing to match. A web application firewall that parses shopper HTTP at the public grocery storefront is the wrong fit because storefront HTTP is a different flow, and that parser does not sit on pod virtual interfaces inside the node. A passive intrusion sensor on the internet edge that alerts on inbound scans is the wrong fit because an edge sensor can raise an alert on internet scans and does not enforce conversations that stay inside the node. Exam caveat: The program has to be present on every node the pods can be scheduled onto, including nodes an autoscaler adds later, or a moved pod leaves the policy behind. Operational check: Place two test pods on one node, send a flow the policy should deny, and confirm the deny is logged on that node while the upstream appliance log stays empty.