Hotel marketing staff may read a social site from the corporate network, but they are not allowed to post. Which secure web gateway control fits that split?
Select an answer to reveal the explanation.
Short Explanation
Guests may read the lobby paper, but they may not scribble an official notice in the margin. You use application control to block posting while reads of the social site still work. The trap is a category block that also stops the reading the hotel still allows.
Full Explanation
Application control at the secure web gateway can distinguish activities on the same site, so blocking the post activity stops publishing while reads of the social site still succeed. A category block on the whole social site is coarser and stops both reading and posting, which violates the reading allowance. Blocking the social domain in DNS stops name resolution, so the site does not load and reading fails along with posting. A data-loss rule that blocks every spreadsheet upload looks for sensitive file content on a different action and leaves the social posting activity untouched. Exam caveat: the gateway can make that activity split only when the session is decrypted and the client is actually on the proxy. Operational check: from a marketing test identity, open the social site and confirm a read succeeds, then attempt a post and confirm application control blocks only that activity. Record the rule name on the post, keep the successful read in the same test, and store both log lines with the marketing identity so the split is still visible after the next policy push.