A grain-handling facility installs a new 30-foot vertical fixed steel ladder on the exterior of a storage bin for routine roof-hatch access. Under OSHA's general industry Walking-Working Surfaces standard (29 CFR 1910.28), what fall protection must be installed on this new fixed ladder?
Select an answer to reveal the explanation.
Short Explanation
You’ll want to remember that new fixed ladders over 24 feet need fall protection. A steel safety cage or a higher 35-foot exemption won’t meet the requirement; install a personal fall arrest system or a ladder safety system.
Full Explanation
Under 29 CFR 1910.28, fixed ladders extending more than 24 feet above a lower level require fall protection. For a fixed ladder installed on or after November 19, 2018, the employer must provide a personal fall arrest system or a ladder safety system. These systems arrest a climber’s fall over a short distance rather than allowing a long drop. A wraparound steel safety cage with a rest platform every 20 feet does not meet the requirement for a new fixed ladder: OSHA phased out cages and wells as acceptable protection because climbers can still fall inside an enclosure and suffer severe impacts. An administrative policy requiring two workers to spot from the ground provides no physical fall-arrest capability and does not satisfy the standard. The claim that fixed ladders are exempt up to 35 feet misstates the 24-foot threshold. Exam caveat: existing fixed ladders installed before November 19, 2018 may temporarily retain cages until replacement or the 2036 phase-out deadline, unless replaced sooner. Practical check: inspect the vertical rail or cable carrier, verify compatible shuttle locks are available, and confirm climbers are trained to connect before ascent.
Prefer to study offline? Printable PDF study book + test engine ($7.50, unofficial). These questions stay free here.