A manufacturing plant maintains written machine-specific lockout/tagout procedures for its automated packaging lines. Under OSHA's Control of Hazardous Energy standard (29 CFR 1910.147), how often and by whom must the periodic inspection of these energy control procedures be performed?
Select an answer to reveal the explanation.
Short Explanation
Lockout procedures are not 'set it and forget it' paperwork—and you shouldn't grade your own homework! The trap is picking the wrong inspection interval or letting the person doing the lockout certify their own steps.
Full Explanation
Under 29 CFR 1910.147, the employer must conduct a periodic inspection of each energy control procedure At least annually by an authorized employee not using the procedure being inspected. Having an independent authorized employee observe the lockout in action ensures that deviations, missing isolation points, or misunderstood steps are caught objectively and corrected before an unexpected startup occurs. Selecting Every five years by the original maintenance technician who wrote the procedure is noncompliant. The five-year interval is what makes that option noncompliant. Selecting Every two years by an external OSHA compliance officer during a site visit is incorrect because periodic inspections are an ongoing employer responsibility, not an enforcement audit, and two years exceeds the annual limit. Selecting Monthly by any affected machine operator working on the production line assigns the duty to an affected employee rather than an authorized employee qualified to perform lockout/tagout. Caveat: the annual inspection must also include a review between the inspector and each authorized employee (and affected employees where tagout is used) regarding their responsibilities. As an operational check, audit the signed annual certification records showing the machine, date, employees included, and inspector.
Prefer to study offline? Printable PDF study book + test engine ($7.50, unofficial). These questions stay free here.