During a reactor maintenance entry, an adult worker receives a uniform whole-body external absorbed dose of 20 mrad from gamma rays and 5 mrad from neutrons of unknown energy. Under NRC 10 CFR 20.1004, what is the worker's total external dose equivalent?
Select an answer to reveal the explanation.
Short Explanation
Think of quality factors like biological multipliers that scale raw absorbed energy into tissue risk. Under 10 CFR 20.1004, neutrons of unknown energy carry a multiplier of 10, not 1 or 20, so you scale only the neutron dose before adding the gamma component. The classic trap is adding the raw millirad numbers directly or applying the alpha multiplier to neutrons.
Full Explanation
Under NRC 10 CFR 20.1004, external absorbed dose in rad is converted to dose equivalent in rem by multiplying each radiation component by its assigned quality factor. Gamma rays carry a quality factor of 1, so 20 mrad of gamma exposure equals 20 mrem. Neutrons of unknown energy carry a quality factor of 10, so 5 mrad of neutron exposure equals 50 mrem. Summing the two weighted components yields 70 mrem total external dose equivalent. Choosing 25 mrem total external dose equivalent fails because it adds the raw absorbed doses directly without applying the neutron quality factor of 10. Choosing 120 mrem total external dose equivalent fails because it applies a quality factor of 20, which 10 CFR 20.1004 reserves for alpha particles, multiple-charged particles, and fission fragments rather than neutrons of unknown energy. Choosing 250 mrem total external dose equivalent fails because it mistakenly applies the neutron quality factor of 10 to the combined 25 mrad dose instead of only to the neutron component. As a regulatory caveat, 10 CFR 20.1004 also provides energy-dependent neutron quality factors when the neutron energy spectrum is known, which can differ from the default factor of 10. For an operational check, review the site dosimetry report and neutron-to-gamma ratio from area survey instruments to confirm that both components were weighted separately before recording deep-dose equivalent.
Prefer to study offline? Printable PDF study book + test engine ($7.50, unofficial). These questions stay free here.